A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improved reverse screening algorithm for Treponema pallidum antibody using signal-to-cutoff ratios from chemiluminescence microparticle immunoassay. | LitMetric

Improved reverse screening algorithm for Treponema pallidum antibody using signal-to-cutoff ratios from chemiluminescence microparticle immunoassay.

Sex Transm Dis

From the *State Key Laboratory of Oncology in South China and Departments of †Clinical Laboratory and ‡Thoracic Surgery, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong, China.

Published: January 2014

Background: The widespread reverse syphilis screening algorithm involves 1 more treponemal test than the traditional screening algorithm, resulting in increased medical costs. In the first screening step of the algorithm, a chemiluminescence microparticle immunoassay is used to detect Treponema pallidum (TP) antibody on the basis of signal-to-cutoff (S/CO) ratios. We hypothesized that by analyzing S/CO ratios, we could determine a strategy to reduce unnecessary confirmatory testing.

Methods: The ARCHITECT Syphilis TP assay using the chemiluminescence microparticle immunoassay was used as a syphilis screening test, and all reactive results were followed up with a toluidine red unheated serum test (TRUST) and a TP particle agglutination (TPPA) assay. We evaluated the S/CO ratios of 319 reactive samples of a total of 8980 that were included in the screening tests. A receiver operating characteristic curve was used to determine the optimal S/CO ratio to predict confirmatory TPPA results.

Results: When the S/CO ratio was 9.9 or greater, the specificity and positive predictive value were both determined to be 100.0%. All samples (194/194) with S/CO ratios of 9.9 or greater, even with negative results for TRUST, were confirmed to be positive for treponemal antibody.

Conclusions: A sample with an S/CO ratio of 9.9 or greater in initial screening does not need an extra confirmatory TPPA test, although the sample has a negative result for TRUST. We propose a potentially cost-effective reverse screening algorithm, obviating the need for the secondary treponemal testing in 65.2% of the screening-reactive samples.

Download full-text PDF

Source
http://dx.doi.org/10.1097/OLQ.0000000000000066DOI Listing

Publication Analysis

Top Keywords

screening algorithm
16
s/co ratios
16
chemiluminescence microparticle
12
microparticle immunoassay
12
s/co ratio
12
screening
8
reverse screening
8
treponema pallidum
8
pallidum antibody
8
syphilis screening
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!