This study analyzed the results of 3,701 patients implanted with cardiac pacemakers at the Centre Chirurgical du Val d'Or between 1976 and 1981. Two pacemaker populations were compared: those having a new pacemaker and those implanted with a reused pacemaker. There were no statistically significant differences between the two groups, either in terms of indications for implantation or in terms of actuarial survival of patients. In addition, there was no significant change in survival of the pulse generator. The reutilization of pacemakers appeared to be in no way detrimental to patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8159.1986.tb06709.x | DOI Listing |
J Cardiovasc Electrophysiol
January 2025
TriHealth Heart & Vascular Institute, Cincinnati, Ohio, USA.
Introduction: A leadless pacemaker (LLPM) was recommended for a patient with intermittent complete heart block and near-syncope.
Methods And Results: Delivery of LLPM is through a large sheath that has limited deflection and steerability. This report describes the successful deployment of a ventricular LLPM in a patient with prior surgical correction of AV septal defect with subsequent significant right atrial enlargement.
Vet Sci
January 2025
Department of Clinics, Faculty of Veterinary Medicine, "Ion Ionescu de la Brad" Iasi University of Life Sciences, 700490 Iasi, Romania.
A 3-year-old spayed male mixed-breed Labrador presented to the Emergency and Critical Care Unit with lethargy, loss of appetite, vomiting, a recent history of presyncopal episodes, and severe exercise intolerance. On admission, the patient had bradycardia, low blood pressure, and mild abdominal pain. Serum biochemistry information revealed severe hyperkalemia, hyponatremia, hypoglycemia, and mildly increased liver and kidney parameters.
View Article and Find Full Text PDFJ Cardiovasc Dev Dis
December 2024
Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, 20132 Milan, Italy.
Transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis and raphe-type bicuspid aortic valve (BAV) is still associated with poor outcomes in terms of increased risk of paravalvular regurgitation, stroke, and permanent pacemaker implantation. There is no definitive consensus on the optimal sizing method for prosthesis selection in this setting. The LIRA method is a supra-annular tailored sizing method specifically designed for bicuspid anatomy that might increase accuracy of prosthesis choice in BAV patients and improve TAVR outcomes.
View Article and Find Full Text PDFInnovations (Phila)
January 2025
Division of Cardiothoracic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
Objective: Percutaneous vegetation debulking has been reported to treat tricuspid valve infective endocarditis (TVIE), but data on feasibility compared with conventional surgical strategies are limited. We aimed to compare short-term outcomes of suction debulking with partial venovenous bypass to conventional open surgery in this population.
Methods: This was a single-center, retrospective study that included all patients with isolated TVIE who underwent suction debulking with partial venovenous bypass or tricuspid valve surgery between January 2010 and December 2022.
BMC Surg
January 2025
Department of Cardiothoracic Surgery, Heart Center, School of Medicine, Shanghai Children's Medical Center, Shanghai Jiaotong University, Shanghai, China.
Purpose: An anomalous aortic origin of the coronary artery (AAOCA) is a rare congenital heart disease. Some high-risk anatomical structures are at risk of inducing cardiogenic shock or even sudden death. This article summarizes our surgical experience with AAOCA in paediatric patients.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!