Background: The purpose of this in-vitro study was to compare canal transportation and centering ability of Twisted and Hyflex Rotary Files with stainless steel hand k-flexofiles by using Spiral Computed Tomography.
Materials & Methods: A total of 90 freshly extracted human mandibular single rooted Premolar teeth were selected. The crowns were flattened with steel disks and a final dimension of 18-mm WL was achieved for each tooth. Canals were divided randomly into 3 groups of 30 teeth each. Group I:Hyflex files, Group II:Twisted files, Group III:stainless steel hand k-flexofiles. Three sections from apical, mid-root, and coronal levels of the canal were recorded. All the teeth were scanned before and after instrumentation by using Spiral Computed Tomography.
Results: K-files showed highest transportation and less centered when compared to the Twisted and Hyflex rotary files. No significant difference was found between TF and Hyflex CM instruments.
Conclusion: TF and Hyflex files shaped curved root canals without significant shaping errors when compared to the Hand stainless steel k-flexofiles. How to cite this article: Kumar BS, Pattanshetty S, Prasad M, Soni S, Pattanshetty KS, Prasad S. An in-vitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography. J Int Oral Health 2013;5(5):108-15.