Objectives: To determine outcomes following balloon aortic valvuloplasty (BAV) in aortic stenosis (AS) patients with a left ventricular ejection fraction (LVEF) <20%.

Background: Severe AS patients with a LVEF <20% are excluded from United States (U.S.) transcatheter aortic valve replacement (TAVR) trials and often surgical aortic valve replacement (AVR). The role for BAV to enhance LVEF is unclear.

Methods: Our BAV database of 270 consecutive patients extending from 2005 through 2010 was queried for a preoperative LVEF <20%. Demographics, echocardiograms, procedural technique, and outcomes were analyzed. Pre- and postoperative echocardiograms were used to determine improvement in aortic valve area (AVA) and LVEF.

Results: Sixteen patients were identified with a median age of 82 years. The composite Society of Thoracic Surgeons' (STS) mortality risk was 16.4%. The median preoperative AVA and LVEF were 0.60 cm(2) and 16%, respectively, and postoperative AVA and LVEF were 0.77 cm(2) and LVEF 19%, respectively. About 15 of the 16 patients had postoperative echocardiograms available for comparison. And 7 of these 15 (47%) demonstrated improvement in LVEF to ≥20% (median LVEF 25%). The absence of coronary disease and improvement in AVA of ≥0.2 cm(2) was associated with postoperative LVEF of ≥20%. Procedural mortality was 0%. The 30-day, 6-month, and 1-year survival was 69%, 56%, and 29%. STS's mortality risk score ≥15% was associated with short-term mortality.

Conclusion: With appropriate technique, BAV can be reasonably safe in patients with LVEF <20%. Roughly half of these patients demonstrated improvement in LVEF to ≥20%.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.25328DOI Listing

Publication Analysis

Top Keywords

balloon aortic
4
aortic valvuloplasty
4
valvuloplasty high
4
high risk
4
risk aortic
4
aortic stenosis
4
stenosis patients
4
patients left
4
left ventricular
4
ventricular ejection
4

Similar Publications

Postinfarction ventricular septal rupture (PIVSR) is a rare but serious complication of acute myocardial infarction. Determining how to conduct surgical repair safely is critical. We compared the outcomes of Impella and intra-aortic balloon pump (IABP) implantation during perioperative mechanical circulatory support management in patients with PIVSR (n = 22).

View Article and Find Full Text PDF

: In-hospital mortality associated with myocardial infarction complicated by cardiogenic shock (MI-CS) remains critically high. A particularly challenging form, mixed shock (MS), combines features of cardiogenic shock (CS) with distributive elements such as vasodilation and reduced vascular resistance. MS is associated with elevated mortality rates and presents unique diagnostic and therapeutic challenges.

View Article and Find Full Text PDF

Purpose: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is beneficial for uncontrollable torso bleeding; however, prolonged REBOA causes ischemia-reperfusion injury. The purpose of this study is to examine the hypothesis that continuous renal replacement therapy (CRRT) with a cytokine-adsorbing hemofilter would improve mortality due to hemorrhagic shock with REBOA-reperfusion injury by controlling metabolic acidosis, hyperkalemia, and hypercytokinemia.

Methods: Hemorrhagic shock with 40% blood loss was induced by phlebotomy in eight female swine.

View Article and Find Full Text PDF

Novel Real-Time Fluoroscopic Assessment Method of Transcatheter Heart Valve Expansion Following Balloon-Expandable TAVR.

Circ Cardiovasc Interv

January 2025

Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, Canada. (A.H., J.J., S.O., K.M., J.A.L., P.B., D.A.W., S.L.S., J.G.W., J.S.).

Background: Transcatheter heart valve (THV) underexpansion after transcatheter aortic valve replacement may be associated with worse outcomes. THV expansion can be assessed fluoroscopically using a pigtail for calibration; however, the accuracy of this technique specific to transcatheter aortic valve replacement is unknown. We assessed the accuracy and reproducibility of a novel fluoroscopic method to assess THV expansion using the THV commissural post for calibration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!