Broadband all-optical microwave photonics phase detector. | LitMetric

A microwave photonics phase detector is conceived and practically demonstrated. The phase-detector system employs a semiconductor optical amplifier as a four-wave mixer to enable phase detection over a broad frequency range. The system behavior is first mathematically modeled and then demonstrated practically. Phase measurement over a frequency range of 1-18 GHz is achieved. This phase detector is an excellent candidate for wideband applications such as frequency-agile radar.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.38.005256DOI Listing

Publication Analysis

Top Keywords

phase detector
12
microwave photonics
8
photonics phase
8
frequency range
8
phase
5
broadband all-optical
4
all-optical microwave
4
detector microwave
4
detector conceived
4
conceived practically
4

Similar Publications

The albumin-bilirubin (ALBI) score was recently used to predict hepatic reserve. This score is a continuous variable that is used to determine cutoff values and is easily calculated from albumin and bilirubin levels alone. Thus, we aimed to investigate whether the ALBI score could predict a decreased hepatic parenchymal contrast enhancement (HPCE) during the portal phase of dynamic multi-detector computed tomography in patients with liver cirrhosis (LC).

View Article and Find Full Text PDF

The quantitation of the major capsid protein L1 is an important metric during the pharmaceutical manufacturing of human papilloma virus (HPV) vaccines, as they are critical components of virus like particles (VLPs) that form the core of the drug product. During the production of VLPs, the L1 protein is present in multiple states, including monomer, multimer, fully formed VLPs and aggregate species, whose expression levels provides an important read-out of upstream productivity and downstream purification efficiency through the measurement of step yields. However, quantitation of total L1 protein is challenging not only due to its presence in multiple states, but also due to the matrix complexity and purification stage of the samples, which spans complex cell lysate to cleaner post purification material.

View Article and Find Full Text PDF

Enhancing Interferometry Using Weak Value Amplification with Real Weak Values.

Phys Rev Lett

February 2025

University of Ottawa, Department of Physics and Nexus for Quantum Technologies, 25 Templeton Street, Ottawa, Ontario, Canada K1N 6N5.

We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components.

View Article and Find Full Text PDF

The ringdown phase following a binary black hole coalescence is a powerful tool for measuring properties of the remnant black hole. Future gravitational wave detectors will increase the precision of these measurements and may be sensitive to the environment surrounding the black hole. This work examines how environments affect the ringdown from a binary coalescence.

View Article and Find Full Text PDF

A femtosecond pulse downconverts broadband electromagnetic signals to the hundreds of MHz range, enabling fast measurement and enhancing electromagnetic monitoring efficiency. However, due to the high peak power of optical pulses, the received power of the detector is severely limited, and thus the sensitivity of the system is reduced. To address this problematic issue, this paper presents a multichannel parallel high-saturation optical power-balanced photodetection technique that uses parallel reception to enhance the detector's received power, thereby improving the signal-to-noise ratio (SNR) and system sensitivity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!