Purpose: To improve the diagnostic quality of CT pulmonary angiography (CTPA) by individually optimizing a biphasic contrast injection function to achieve targeted uniform contrast enhancement. To compare the results against a previously reported discrete Fourier transform (DFT) approach.

Methods: This simulation study used the CTPA datasets of 27 consecutive patients with pulmonary thromboembolic disease (PE). An optimization approach was developed consisting of (1) computation of the impulse enhancement function (IEF) based on a test bolus scan, and (2) optimization of a biphasic contrast injection function using the IEF in order to achieve targeted uniform enhancement. The injection rates and durations of a biphasic contrast injection function are optimized by minimizing the difference between the resulting contrast enhancement curve and the targeted uniform enhancement curve, while conforming to the clinical constraints of injection rate and total contrast volume. The total contrast volume was limited first to the clinical standard of 65 ml, and then to the same amount used in the DFT approach for comparison. The optimization approach and the DFT approach were compared in terms of the root mean square error (RMSE) and total contrast volume used.

Results: When the total contrast volume was limited to 65 ml, the optimization approach produced significantly better contrast enhancement (closer to the targeted uniform contrast enhancement) than the DFT approach (RMSE 17 HU vs 56 HU, p < 0.00001). On average, the optimization approach used 63 ml contrast, while the DFT approach used 50 ml with four patients exceeding 65 ml. When equivalent total contrast volume was used for individual patient, the optimization approach still generated significantly better contrast enhancement (RMSE 44 HU vs 56 HU, p < 0.01). Constraints for the injection function could be easily accommodated into the optimization process when searching for the optimal biphasic injection function.

Conclusions: The optimization approach generated individually optimized biphasic injection functions yielding significantly better contrast enhancement compared to the DFT approach. This new approach has the potential to improve the diagnostic quality of CTPA for PE.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4829529DOI Listing

Publication Analysis

Top Keywords

contrast enhancement
28
optimization approach
24
total contrast
20
contrast volume
20
dft approach
20
contrast
16
injection function
16
targeted uniform
16
uniform contrast
12
biphasic contrast
12

Similar Publications

Purpose: This case report aims to present a rare case of endometrial carcinosarcoma, a highly malignant tumor with a poor prognosis. The primary objective is to describe this unique case's clinical presentation, multimodal magnetic resonance imaging (MRI) features, typical histopathological characteristics and surgical treatment.

Methods: A detailed analysis of the patient's medical history, preoperative imaging evaluation, and treatment approach was conducted.

View Article and Find Full Text PDF

This study aims to shed light on the mechanism and kinetics of 1,4-dioxane degradation by hydroxyl radical (OH) across various solvation conditions to evaluate electronic and structural properties at the MP2/aug-cc-pVTZ level. Transition states (TS) structures determined in the gas phase and SMD solvation model reveal similar hydrogen abstraction patterns. In contrast, the explicit solvation model (ES) introduces significant changes, suggesting a kinetic preference for axial pathways.

View Article and Find Full Text PDF

: This study aimed to evaluate the diagnostic performance of the Kaiser score (KS) on the modified abbreviated breast magnetic resonance imaging (AB-MRI) protocol for characterizing breast lesions by comparing it with full-protocol MRI (FP-MRI), using the histological data as the reference standard. : Breast MRIs detecting histologically verified contrast-enhancing breast lesions were evaluated retrospectively. A modified AB-MRI protocol was created from the standard FP-MRI, which comprised axial fat-suppressed T2-weighted imaging (T2WI), pre-contrast T1-weighted imaging (T1WI), and first, second, and fourth post-contrast phases.

View Article and Find Full Text PDF

A Comparison Study of Person Identification Using IR Array Sensors and LiDAR.

Sensors (Basel)

January 2025

Faculty of Science and Technology, Keio University, Yokohama 223-8522, Japan.

Person identification is a critical task in applications such as security and surveillance, requiring reliable systems that perform robustly under diverse conditions. This study evaluates the Vision Transformer (ViT) and ResNet34 models across three modalities-RGB, thermal, and depth-using datasets collected with infrared array sensors and LiDAR sensors in controlled scenarios and varying resolutions (16 × 12 to 640 × 480) to explore their effectiveness in person identification. Preprocessing techniques, including YOLO-based cropping, were employed to improve subject isolation.

View Article and Find Full Text PDF

Large visual language models like Contrastive Language-Image Pre-training (CLIP), despite their excellent performance, are highly vulnerable to the influence of adversarial examples. This work investigates the accuracy and robustness of visual language models (VLMs) from a novel multi-modal perspective. We propose a multi-modal fine-tuning method called Multi-modal Depth Adversarial Prompt Tuning (MDAPT), which guides the generation of visual prompts through text prompts to improve the accuracy and performance of visual language models.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!