A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Histopathological assessment of fatal ipsilateral intraparenchymal hemorrhages after the treatment of supraclinoid aneurysms with the Pipeline Embolization Device. | LitMetric

Object: Delayed ipsilateral intraparenchymal hemorrhage has been observed following aneurysm treatment with the Pipeline Embolization Device (PED). The relationship of this phenomenon to the device and/or procedure remains unclear. The authors present the results of histopathological analyses of the brain sections from 3 patients in whom fatal ipsilateral intracerebral hemorrhages developed several days after uneventful PED treatment of supraclinoid aneurysms.

Methods: Microscopic analyses revealed foreign material occluding small vessels within the hemorrhagic area in all patients. Further analyses of the embolic materials using Fourier transform infrared (FTIR) spectroscopy was conducted on specimens from 2 of the 3 patients. Although microscopically identical, the quantity of material recovered from the third patient was insufficient for FTIR spectroscopy.

Results: FTIR spectroscopy showed that the foreign material was polyvinylpyrrolidone (PVP), a substance that is commonly used in the coatings of interventional devices.

Conclusions: These findings are suggestive of a potential association between intraprocedural foreign body emboli and post-PED treatment-delayed ipsilateral intraparenchymal hemorrhage.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2013.11.JNS131599DOI Listing

Publication Analysis

Top Keywords

ipsilateral intraparenchymal
12
fatal ipsilateral
8
treatment supraclinoid
8
pipeline embolization
8
embolization device
8
intraparenchymal hemorrhage
8
foreign material
8
ftir spectroscopy
8
histopathological assessment
4
assessment fatal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!