A survey of central venous catheter practices in Australian and New Zealand tertiary neonatal units.

Aust Crit Care

Monash Newborn, Monash Medical Centre, Clayton, Australia; Monash Institute of Medical Research, Monash University, Clayton, Australia.

Published: February 2014

AI Article Synopsis

  • The study investigates the current medical and nursing practices for managing central venous catheters (CVCs) in neonatal intensive care units (NICUs) across Australia and New Zealand, comparing them with CDC guidelines.
  • The survey indicated that while most NICUs had guidelines for CVC management, the practices varied significantly, especially regarding skin disinfection and the use of sterile barriers during insertion.
  • Less than half of the NICUs provided education on CVC management, highlighting a potential gap in training and adherence to best practices.

Article Abstract

Background: Infection is the most common problem with central venous catheters (CVCs) in neonates. There are two published guidelines, including the Centers for Disease Control and Prevention (CDC), for the prevention of intravascular catheter-related infection that describes evidence-based practice to reduce nosocomial infection.

Objective: Our aims were to survey current medical and nursing management of central venous catheters in tertiary neonatal intensive care units in Australia and New Zealand and to compare with the CDC evidence-based practice guideline.

Methods: A cross sectional survey was performed across 27 Australian and New Zealand neonatal units in September 2012. Two web-based questionnaires were distributed, one to medical directors related to the insertion of CVCs while CVC "maintenance" surveys were sent to nurse unit managers.

Results: Seventy percent (19/27) medical management and 59% (16/27) on nursing management surveys were completed. In all neonatal intensive care units (NICUs) there were guidelines for CVC maintenance and for 18 out of 19 there were guidelines for insertion. In the seven units using femoral lines, three had a guideline on insertion and four for maintenance. CVC insertion was restricted to credentialed staff in 57.9% of neonatal units. Only 26.5% used full maximal sterile barriers for insertion. Skin disinfection practices widely varied. Dressing use and dressing change regimens were standardised; all using a semi-permeable dressing. Duration of cleaning time of the access point varied significantly; however, the majority used a chlorhexidine with alcohol solution (68.8%). Line and fluid changes varied from daily to 96 h. The majority used sterile gloves and a sterile dressing pack to access the CVC (68.8%). In the majority of NICUs stopcocks were used (62.5%) with a needle-less access point attached (87.5%). In less than 50% of NICUs education was provided on insertion and maintenance.

Conclusion: There is diversity of current practices and some aspects vary from the CDC guideline. There is a need to review NICU current practices to align with evidence based guidelines. The introduction of a common guideline may reduce variations in practice.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aucc.2013.11.002DOI Listing

Publication Analysis

Top Keywords

central venous
12
neonatal units
12
australian zealand
8
tertiary neonatal
8
venous catheters
8
evidence-based practice
8
nursing management
8
neonatal intensive
8
intensive care
8
care units
8

Similar Publications

Introduction: Japanese encephalitis virus (JEV) and Zika virus (ZIKV) are prevalent in over 80 countries or territories worldwide, causing hundreds of thousands of cases annually. But currently there is a lack of specific antiviral agents and effective vaccines.

Methods: In the present study, to identify human neutralizing monoclonal antibody (mAb) against JEV or/and ZIKV, we isolated ZIKV-E protein-binding B cells from the peripheral venous blood of a healthy volunteer who had received the JEV live-attenuated vaccine and performed 10× Genomics transcriptome sequencing and BCR sequencing analysis, we then obtained the V region amino acid sequences of a novel mAb LZY3412.

View Article and Find Full Text PDF

Cardiac return assist blanket (CRAB) safely increases central venous pressure.

J Int Med Res

January 2025

Institute for Health Research, the University of Notre Dame Australia, Department of Research, Sir Charles Gairdner Hospital, Nedlands, Australia.

Objective: The cardiac return assist blanket (CRAB) has been designed to increase central venous pressure (CVP) to manage severe hypotension associated with anaphylaxis. This interventional study aimed to identify the relationship between CRAB pressure and CVP. CRAB pressure was also compared with the change in CVP associated with a straight leg raise (SLR), the Trendelenburg position, and 1 L of compound sodium lactate.

View Article and Find Full Text PDF

Background: Venous waveform analysis is an emerging technique to estimate intravascular fluid status by fast Fourier transform deconvolution. Fluid status has been shown proportional to , the amplitude of the fundamental frequency of the waveform's cardiac wave upon deconvolution. Using a porcine model of distributive shock and fluid resuscitation, we sought to determine the influence of norepinephrine on of the central venous waveform.

View Article and Find Full Text PDF

Objective: Radiographic findings to identify central venous catheter misplacement in the arteries, which can cause lethal complications, have not been fully evaluated, and its training is difficult because it is rare. The purpose of this study is to clarify radiographic findings for differentiating central venous and misplaced arterial lines using virtual chest radiographs and elucidate their usefulness in training radiologists.

Methods: This retrospective study included 150 patients (mean age, 67 [SD, ±12] years; 97 men) who underwent colon cancer surgery between January 2018 and December 2020.

View Article and Find Full Text PDF

This nurse-led research study investigates the comparative effectiveness of heparin versus 0.9% sodium chloride locking in blood cancer patients with peripherally inserted central catheters (PICCs). Subjects were randomly assigned to receive either heparin or 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!