Spinal instrumentation and fusion have been incriminated as contributing to adjacent segment degeneration (ASD). It has been suggested that ASD results from increased range of motion and intradiscal pressure (IDP) adjacent to instrumentation. Posterior dynamic stabilization with polyetheretherketone (PEEK) rods has been proposed as potentially advantageous compared to rigid instrumentation with titanium (Ti) rods in reducing the incidence of ASD. We evaluated segmental motions in the cadaveric spine instrumented with PEEK or Ti rods from L3 to S1, as well as the adjacent segment motions and IDP at L1-2 and L2-3. Human cadaveric spines were potted at T12-L1 and S1-2. Spinal instrumentation from L3-S1 was accomplished using pedicle screws with either PEEK or Ti rods. Specimens were subjected to displacement controlled testing: 15° flexion, 15° extension, 10° lateral bending, and 5° right axial rotation using the MTS machine (MTS, Minneapolis, MN, USA). Intradiscal pressure was measured by placing pressure transducers into the intervertebral disc at L1-2 and L2-3. Spinal motion of L2 relative to L3, and L3 relative to S1 was tracked using a three dimensional motion analysis system. Instrumentation with PEEK and Ti rods was associated with a decrease in L3-S1 motion compared to the intact state that was significant in flexion (p=0.002), and extension (p=0.0075). Instrumentation with PEEK and Ti rods was associated with an increase in IDP at L1-2 that was significant in flexion (p=0.0028). Instrumentation with either PEEK or Ti rods resulted in decreased motion at the instrumented levels while increasing IDP at the adjacent level.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jocn.2013.08.010 | DOI Listing |
BMC Musculoskelet Disord
August 2024
Research Unit of Orthopaedic and Trauma Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, Roma, 00128, Italy.
Purpose: Implanted devices used in metastatic spine tumor surgery (MSTS) include pedicle screws, fixation plates, fixation rods, and interbody devices. A material to be used to fabricate any of these devices should possess an array of properties, which include biocompatibility, no toxicity, bioactivity, low wear rate, low to moderate incidence of artifacts during imaging, tensile strength and modulus that are comparable to those of cortical bone, high fatigue strength/long fatigue life, minimal or no negative impact on radiotherapy (RT) planning and delivery, and high capability for fusion to the contiguous bone. The shortcomings of Ti6Al4V alloy for these applications with respect to these desirable properties are well recognized, opening the field for an investigation about novel biomaterials that could replace the current gold standard.
View Article and Find Full Text PDFZhongguo Gu Shang
July 2024
Department of Orthopaedics, Dongzhimen Hospital Affiliated to Beijing University of Chinese Medicine, Beijing 100700, China.
Objective: To investigate the effect of Polyetheretherketone (PEEK) rod semi-rigid pedicle screw fixation system in lumbar spine non-fusion surgery.
Methods: A total of 74 patients with tow-level lumbar degenerative diseases who underwent surgery from March 2017 to December 2019 were divided into PEEK rod group and titanium rod group. In the PEEK rod group, there were 34 patients, including 13 males and 21 females, aged from 51 to 79 years old with an average of (62.
Front Bioeng Biotechnol
July 2024
Department of Orthopedics, Peking University First Hospital, Beijing, China.
Neurospine
June 2024
Department of Neurosurgery, Dongzhimen Hospital, Beijing University of Traditional Chinese Medicine, Beijing, China.
Objective: To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods: A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1-4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected.
BMC Musculoskelet Disord
June 2024
Orthopedic Department, 960 Hospital of People's Liberation Army, NO.25 Shifan Road, Jinan, Shandong, 250031, China.
Purpose: To analyze the characteristics of PEEK rods retrieved in vivo, specifically their wear and deformation, biodegradability, histocompatibility, and mechanical properties.
Method: Six PEEK rods were retrieved from revision surgeries along with periprosthetic tissue. The retrieved PEEK rods were evaluated for surface damage and internal changes using Micro-CT, while light and electron microscopy were utilized to determine any histological changes in periprosthetic tissues.