Although rotational parameters by speckle tracking echocardiography (STE) have been previously compared to sonomicrometry and cardiac magnetic resonance imaging, few have examined the relationship between left ventricular (LV) rotational mechanics and intraventricular measures of load-independent contractility, LV stiffness, or ventriculoarterial coupling. The aim of this study was to compare the changes in LV rotational indices to intraventricular pressure-volume (PV) relationships under a range of inotropic states induced by pharmacological interventions, acute ischemia, and changes in preload. In nine pigs, simultaneous echocardiographic imaging and LVPV measurements were performed during pharmacologically induced high or low inotropy and during acute ischemia by ligation of the left anterior descending coronary artery (LAD). Maximal ventricular elastance (Emax), arterial elastance (Ea), ventricular-arterial coupling (Emax/Ea), dP/dt, tau, and other hemodynamic parameters were determined. Dobutamine and esmolol infusions led to inversely correlated changes in hemodynamic measurements of LV function. Apical but not basal rotation and diastolic rotation rate were decreased by esmolol and increased by dobutamine. The LV twist correlates well with Emax (r = 0.83) and Emax/Ea (r = 0.80). Apical diastolic rotation rate also correlates with dP/dtmin (r = -0.63), τ (r = -0.81), and LV stiffness (r = -0.52). LAD ligation decreased systolic and diastolic LV rotation in apical (P < 0.05), but not basal myocardium. Occlusion of the inferior vena cava, to reduce preload, increased apical rotation in systole and diastole. LV rotational parameters measured by STE provide quantitative and reproducible indices of global LV systolic and diastolic function during acute changes in hemodynamics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3841045PMC
http://dx.doi.org/10.1002/phy2.110DOI Listing

Publication Analysis

Top Keywords

diastolic rotation
12
left ventricular
8
rotational parameters
8
acute ischemia
8
rotation rate
8
systolic diastolic
8
rotation
5
ventricular twist
4
twist untwist
4
untwist rate
4

Similar Publications

Computational exploration of injection strategies for improving medicine distribution in the liver.

Comput Biol Med

December 2024

Faculty of Chemical & Petroleum Engineering, University of Tabriz, Tabriz, Iran. Electronic address:

Background And Objectives: The liver, a vital metabolic organ, is always susceptible to various diseases that ultimately lead to fibrosis, cirrhosis, acute liver failure, chronic liver failure, and even cancer. Optimal and specific medicine delivery in various diseases, hepatectomy, shunt placement, and other surgical interventions to reduce liver damage, transplantation, optimal preservation, and revival of the donated organ all rely on a complete understanding of perfusion and mass transfer in the liver. This study aims to simulate the computational fluid dynamics of perfusion and the temporal-spatial distribution of a medicine in a healthy liver to evaluate the hemodynamic characteristics of flow and medicine transport with the purpose of more effective liver treatment.

View Article and Find Full Text PDF

Background: Patients with chronic kidney disease (CKD) undergoing maintenance haemodialysis (MHD) develop several abnormalities of left ventricular (LV) structure and function. Speckle-tracking echocardiography permits compressive assessment of LV myocardial deformation. Previous studies involving CKD patients have shown a significant reduction in LV global longitudinal strain (GLS) with strong prognostic implications.

View Article and Find Full Text PDF

Objective: While weight status and clinical laboratory measures are important in assessing obesity-related disease severity and chronic disease risk, including a broader range of emotional, psychosocial, and behavioral factors would provide greater context of an individual's overall state of wellness and could be used to better guide treatment decisions. The purpose of this research was to develop a comprehensive Lifestyle Wellness assessment for use in lifestyle-based wellness interventions and programs.

Methods: A cross-sectional exploratory factor analysis (EFA) was conducted using baseline data from  = 138 adults participating in behavioral weight loss trials.

View Article and Find Full Text PDF

Background: Myxomatous mitral valve disease (MMVD) is the most common acquired heart disease in dogs. Mitral valvuloplasty (MVP) addresses regurgitation, but the pre- and postoperative changes in myocardial function remain uncertain.

Objectives: This study evaluated myocardial motion before and after MVP using two-dimensional speckle-tracking echocardiography (2D-STE).

View Article and Find Full Text PDF
Article Synopsis
  • Modern imaging techniques like CT scans can be used to assess the volume of the coronary sinus, although prior research on this is limited.
  • A study involving 49 patients used a Toshiba Aquilion 64 scanner to measure coronary sinus volume, finding an average volume of 3.71 cm with significant correlation to end diastolic volume.
  • The findings suggest that coronary sinus volume can be effectively visualized and measured using cardiac CT, paving the way for further research in this area.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!