Introduction: Tibial fractures accompanied by radius fractures at typical sites are the most common type of fractures.

Objective: The study is aimed at using the examined sample to make an efficient and economically acceptable choice in the treatment of tibial diaphyseal fractures.

Material And Methods: The series comprises a retrospective and prospective study of the treatment of 131 fresh tibial fractures: 31 in women (23.66%) and 100 in men (76.34%) of the average age of 37.89. Nineteen patients (14.50%) were treated conservatively and 112 (85.50%) surgically: 22 (16.79%) with anti-rotation intramedullary nails, 74 (56.49%) with Mitkovic external fixator type M20, and 16 (12.21%) with locking compression plate. General anaesthesia was used in 46 patients (35.11%), while spinal anaesthesia was used in 85 of them (64.89%).

Results: According to the Karlstrom-Olerud scoring system, the treatment results were as follows: for the 22 tibiae treated with anti-rotation intramedullary nails: in 15 (68.18%) the results were excellent, in 3 (13.64%) they were good and in 4 (18.18%) they were poor. As for the results for the 74 tibiae treated with Mitkovic external fixator type M20, they were as follows: in 62 (83.78%) excellent, in 9 (12.16%) good, and in 3 (4.05%) they were poor. The results for the 16 patients treated with locking compression plate were excellent in 10 (62.50%), good in 2 (12.50%) and poor in 4 patients (25.00%). The treatment results for the 19 tibiae treated with plaster cast were excellent in 12 patients (63.16%), good in 2 (10.53%) and poor in 5 (26.32%). The definite results for the 131 fractured tibiae treated with the aforementioned techniques were as follows: excellent in 99 (75.57%), good in 17 (12.98%) and poor in 15 patients (11.45%).

Discussion: There is a variety of controversial positions concerning the treatment of the tibial diaphysis.

Conclusion: On the basis of the results of surgical treatment for the given series, the number of surgical interventions, the price of osteosynthetic material, my preferences in treating tibial diaphyseal fractures would be as follows: Mitkovic external fixator type M20, anti-rotation intramedullary nails and locking compression plate. Conservative treatment is indicated when the X-ray examination confirms that the fragments have a position acceptable for conservative treatment with plaster cast.

Download full-text PDF

Source
http://dx.doi.org/10.2298/aci1302033gDOI Listing

Publication Analysis

Top Keywords

tibiae treated
16
treatment tibial
12
tibial diaphyseal
12
anti-rotation intramedullary
12
intramedullary nails
12
mitkovic external
12
external fixator
12
fixator type
12
type m20
12
locking compression
12

Similar Publications

Background: Indications for primary total knee arthroplasty (TKA) have become more inclusive of morbidly obese patients, however, higher rates of complications and lower implant survival have also been reported in this population. The purpose of this study was to investigate the mid-term survival, clinical, and radiographic outcomes of a cementless trabecular metal monoblock tibial component in severely obese patients.

Methods: This was a retrospective study of class II and III obese (BMI > 35) patients who received a cementless primary TKA.

View Article and Find Full Text PDF

Incidence of venous thromboembolism in fracture below the knee with and without chemical thromboprophylaxis: a systematic review and meta-analysis.

Arch Orthop Trauma Surg

December 2024

Medical City UNT/TCU Orthopaedic Surgery Residency Program Director, 3325 Medpark Dr, Denton, TX, 76210, USA.

Introduction: Low rates of venous thromboembolism (VTE) have been found in patients with isolated orthopaedic trauma below the knee. Many surgeons routinely provide chemical thromboprophylaxis in these injuries, however. This is not without inherent risks, and this remains a controversial topic in perioperative care in orthopaedic trauma.

View Article and Find Full Text PDF

Background And Purpose:  In total knee arthroplasty (TKA), an insert with ball-in-socket (BS) medial conformity (MC) and posterior cruciate ligament (PCL) retention restores kinematics closer to native than an insert with intermediate (I) MC. However, high medial conformity might compromise baseplate stability as indicated by maximum total point motion (MTPM). Using the BS MC insert with PCL retention, we aimed to determine whether (i) the baseplate is stable as indicated by mean MTPM < 0.

View Article and Find Full Text PDF

Adhesions in the deep infrapatellar region may occur as iatrogenic complications (e.g., after bone-patellar tendon-bone grafting), as part of arthrofibrosis or infrapatellar contracture syndrome, or owing to specific diseases such as Osgood-Schlatter disease.

View Article and Find Full Text PDF

Does the extent of bone defects affect the time to reach full weight-bearing after treatment with the Masquelet technique?

Biomater Biosyst

September 2024

Department of Septic Bone and Joint Surgery, BG Hospital Hamburg, Bergedorfer Straße 10, Hamburg, 21033, Germany.

Methodology: In a consecutive retrospective analysis of 190 patients treated with the Masquelet technique at the BG Klinikum Hamburg from January 2012 to January 2022, subgroup analysis for defect-specific features such as the extent and morphology of the defect were recorded, and their influence on the time to reach full weight-bearing of the affected limb was investigated.

Results And Conclusion: A total of 217 defects were treated in 190 patients using the Masquelet technique. 70 % of all defects were in the tibia, followed by 22 % in the femur and only about 7 % in the upper extremity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!