Here we describe methods for imaging neurons and neuronal excitation in brain slices with infrared video microscopy. Patch clamping in conjunction with a gradient-contrast system allows electrical recording from fine neuronal processes. Imaging with an infrared (IR)-darkfield system allows visualization of the intrinsic optical signal (IOS).

Download full-text PDF

Source
http://dx.doi.org/10.1101/pdb.prot079434DOI Listing

Publication Analysis

Top Keywords

infrared video
8
video microscopy
8
neurons neuronal
8
neuronal excitation
8
excitation brain
8
brain slices
8
system allows
8
microscopy visualizing
4
visualizing neurons
4
slices describe
4

Similar Publications

Itching tends to worsen at night in patients with itchy skin diseases, such as atopic dermatitis. Unconscious scratching during sleep can exacerbate symptoms, cause sleep disturbances, or reduce quality of life. Therefore, evaluating nocturnal scratching behaviour is important for better patient care.

View Article and Find Full Text PDF

Real-Time Quantification of Gas Leaks Using a Snapshot Infrared Spectral Imager.

Sensors (Basel)

January 2025

Department of Optical Engineering, Utsunomiya University, 7-2-1 Yoto, Utsunomiya 321-8585, Japan.

We describe the various steps of a gas imaging algorithm developed for detecting, identifying, and quantifying gas leaks using data from a snapshot infrared spectral imager. The spectral video stream delivered by the hardware allows the system to combine spatial, spectral, and temporal correlations into the gas detection algorithm, which significantly improves its measurement sensitivity in comparison to non-spectral video, and also in comparison to scanning spectral imaging. After describing the special calibration needs of the hardware, we show how to regularize the gas detection/identification for optimal performance, provide example SNR spectral images, and discuss the effects of humidity and absorption nonlinearity on detection and quantification.

View Article and Find Full Text PDF

Camellia oil (CO) is known for its nutritional value and health benefits, but its high price makes it susceptible to adulteration. This study developed a binary adulteration system for CO in response to the adulteration of rapeseed oil (RO) into CO that been observed in the market. A total of 243 oil samples adulterated with various concentrations of RO were prepared.

View Article and Find Full Text PDF

To evaluate whether infrared video imaging can supplement traditional examination and imaging methods to identify and quantify symptomatic vitreous opacities. A prospective nonrandomized nonmasked series was performed that included eyes of consecutive patients with a primary complaint of symptomatic vitreous opacities. A macular vitreous opacity score (0-4) was developed to grade the size of the opacities in relation to the macula after refixation of up, down, left, and right saccades.

View Article and Find Full Text PDF

Purpose: A relative afferent pupillary defect (RAPD) is a characteristic clinical sign of optic neuritis (ON). Here, we systematically evaluated ultrasound pupillometry (UP) for the detection of an RAPD in patients with ON, including a comparison with infrared video pupillometry (IVP), the gold standard for objective pupillometry.

Materials And Methods: We enrolled 40 patients with acute (n = 9) or past (n = 31) ON (ON+), 31 patients with multiple sclerosis (MS) without prior ON, and 50 healthy controls (HC) in a cross-sectional observational study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!