AI Article Synopsis

Article Abstract

Objective: To compare the efficacy and surgical outcome of treatment of anterior mandibular fracture using either 2.0 mm titanium miniplate or 2.4 mm titanium lag screw technique.

Materials And Methods: A total of 30 patients were managed by open reduction and internal fixation utilizing the miniplate and lag screw technique for fractures of anterior mandible. The patients were randomly divided into two groups. Group I: (15 patients) were treated with Leibinger, 2.0 mm titanium mini plates system with self-tapping screws and Group II: (15 patients) were treated with 2.4 mm cortical lag screw (Synthes). Intraoperatively duration of surgery was measured from the time incision was placed till the closure of wound. Subsequent follow up was done at 3, 6, 12, 24 weeks, postoperatively. During every follow up, patients were assessed clinically for malocclusion, neurosensory deficit, biting efficiency, implant failure, mal-union/non-union. Pre and postoperative radiographs were taken to assess the gap between fracture segments. Results were evaluated using Chi square and the unpaired t test.

Results: In our study, the mean duration of surgery (hours) was 1.97 ± 0.52 for group I and 1.26 ± 0.55 for group II. The difference was found to be statistically significant (p value 0.001). i.e. more time was taken in case of surgery with mini-plates when compared to the lag screw. Short surgical procedure reduces the incidence of infectious complications, which significantly lowers the financial burden. The mean post-operative radiographic distance between all measuring points were considerably more in case of mini-plate group as compared to lag screw group. Lag screw group showed faster improvement in terms of biting efficiency as compared to mini-plate group which showed a tendency to masticate only medium hard food items by 24 weeks. In both groups, no postoperative malocclusion was noted. In initial weeks, neurosensory deficit was seen more in mini-plate group as compared to lag screw group but after six weeks all patients showed improvement in neurosensory function without any permanent nerve damage.

Conclusion: According to this prospective study, rigid internal fixation provided by lag screw technique for anterior mandibular fracture offers several advantages over conventional bone plating. It is an excellent means of achieving rapid and safe fixation which is followed by primary bone healing in anterior mandibular fractures, without any major complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3485465PMC
http://dx.doi.org/10.1007/s12663-012-0342-1DOI Listing

Publication Analysis

Top Keywords

lag screw
32
anterior mandibular
16
compared lag
12
mini-plate group
12
screw group
12
group
10
lag
9
mandibular fractures
8
24 mm cortical
8
titanium lag
8

Similar Publications

Objectives: To compare lag-screw slide and revision surgery rate between two generations of the Stryker Gamma cephalomedullary nail (Stryker, Kalamazoo, MI).

Methods: Design: Retrospective chart review.

Setting: Single academic, Level-1 Trauma Center.

View Article and Find Full Text PDF

Subtrochanteric fractures in older patients are typically due to low-energy falls. The standard of care is intramedullary nailing. The Smith & Nephew Trigen Intertan (Memphis, TN, US) is an intramedullary nail with a novel design that incorporates two integrated compression screws.

View Article and Find Full Text PDF

Objective: Despite several surgical options, there has yet to be a consensus on the best treatment for femoral neck fracture (FNF) due to higher complication rates compared to other bone fractures. This study aims to examine the possible consequences and solution suggestions of changing screws during surgery for various reasons in FNF surgical treatment from a biomechanical perspective.

Method: FNF and treatment materials were analyzed biomechanically using a package program based on the finite element method (FEM).

View Article and Find Full Text PDF

Background: This study aimed to analyze the files of patients treated using PFN-A or INTERTAN intramedullary nails to reveal additional superiorities or disadvantageous factors for selecting the better intramedullary fixation method in patients presenting with intertrochanteric femur fractures.

Methods: In this retrospective study, the files of the patients who were operated on for intertrochanteric femur fractures using intramedullary fixation methods between September 2010 and June 2015 in the Orthopedics and Traumatology Clinic, Çukurova University Faculty of Medicine, were reviewed. The data including age, gender, chronic diseases, causes of fractures, fracture classification based on Arbeitsgemeinschaft für Osteosynthesefragen (AO), the nail type (long or short), the interval between trauma and surgery, duration of anesthesia and surgery, hospitalization duration, amount of blood transfusion, the Tip-Apex Distance (TAD) in postoperative radiographs, functional outcomes according to Harris Hip Score (HHS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), postoperative complications, need for revision, and mortality was noted.

View Article and Find Full Text PDF

Background: Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates/screws. We introduced our own surgical approach and reported the clinical/radiographic outcomes via retrospective case series.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!