Bio-resorbable plates as effective implant in paediatric mandibular fracture.

J Maxillofac Oral Surg

Department of Oral & Maxillofacial Surgery, CSM Medical University, Lucknow, 226003 India.

Published: December 2012

AI Article Synopsis

  • The study aimed to evaluate how effective bio-resorbable plates are in treating mandibular fractures in children, using a specific plating system.
  • The results showed significant pain reduction, improved bite force, and good stability of fracture fragments over follow-up periods, although two patients experienced temporary paraesthesia.
  • The conclusion emphasizes the benefits of bio-resorbable plates, which minimize issues like stress shielding and the need for additional surgeries associated with traditional metal implants.

Article Abstract

Aim: To evaluate the efficacy of bio-resorbable plates in paediatric mandibular fracture.

Materials And Methods: In the present study, 40 cases of mandibular fractures were treated by Inion Cps plating system using, 2 and 2.5 mm (LPLA/DLPLA/TMC/PGA) bio-resorbable bone plates and screws of 6 and 8 mm screws. The assessment of the patients was done at 2 week, 1, 3, and 6 months using the clinical parameters and bite force recording.

Results: There was significant reduction in pain at different follow-ups. Paraesthesia was found in two patients with body fracture which remained for 2 week and 1 month follow-up. No paraesthesia was found after 3rd follow-up. Significant stability of fracture fragments were found on different follow ups. Implant exposure was present only in two patients (5%) at 1 month follow up. There was significant increase in incisor, right molar and left molar bite force at 1, 3 and 6 months, from 2nd week onwards.

Conclusion: These findings show that the use of bio-resorbable plates in paediatric mandibular fracture was efficacious enough to bear the masticatory loads during osteosynthesis of the fracture. The recent and significant achievement is the advent of bio-resorbable osteosynthesis devices that has almost solved the problems of stress shielding, secondary surgery and corrosion when metal implants are left-in situ.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3485467PMC
http://dx.doi.org/10.1007/s12663-011-0330-xDOI Listing

Publication Analysis

Top Keywords

bio-resorbable plates
12
paediatric mandibular
12
mandibular fracture
8
plates paediatric
8
bite force
8
bio-resorbable
5
fracture
5
plates effective
4
effective implant
4
implant paediatric
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!