Purpose: In spite of technological breakthroughs, the choice of a suitable location for the coronary sinus (CS) lead in biventricular implants is still mostly empiric. The aim of this study was to investigate the utility of a radiological index-the distance between the right ventricular (RV) and CS lead tips on fluoroscopic recordings, measured by means of a new method-as a tool for selecting the most profitable left ventricular (LV) lead position.
Methods: Forty-nine consecutive patients (36 male, 13female; mean age 63 ± 19 year), in whom the LV electrode was implanted in a lateral/postero-lateral position in the CS, were evaluated immediately after implantation. The fluoroscopic distances between the RV and LV lead tips were calculated off-line in antero-posterior (2DAP) and latero-lateral (2DLL) projections by means of integrated software.
Results: On 1-year follow-up evaluation, 53 % patients were classed as responders (R) (>15 % reduction in LV end-systolic volume) and 47 % as non-responders (NR). On receiver-operating curve analysis, 2DAP and 2DLL showed cut-off values of 81 mm and 51 mm, respectively. In discriminating between R and NR, 2DAP >81 mm displayed 95 % specificity and 74 % sensitivity, while 2DLL >51 mm displayed 74 % specificity and 92 % sensitivity. On multivariate analysis, the cut-off values of 2DAP and 2DLL were significantly predictive of R to CRT.
Conclusions: In our single-center prospective experience, RV-LV interlead distance measured by means of a novel method on fluorographic recordings correlated with CRT response. The use of this method as an intra-operative guide to identifying suitable lead placement in the CS needs evaluating on-line and on a large scale.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10840-013-9843-1 | DOI Listing |
J Pineal Res
August 2022
Department of Cardiac Physiology, Institute of Physiology, Komi Science Center, Ural Branch, Russian Academy of Sciences, Syktyvkar, Russia.
Melatonin treatment was reported to reduce the risk of cardiac arrhythmias, and crucial for this antiarrhythmic action was the effect of melatonin on activation spread. The aim of the present study was evaluation of the mechanisms of this activation enhancement. Experiments were performed in a total of 123 control and melatonin-treated (10 mg/kg, daily, for 7 days) male Wistar rats.
View Article and Find Full Text PDFEpilepsia
January 2020
Department of Neurology and Weill Institute for Neurosciences, University of California San Francisco, San Francisco, CA, USA.
Cardiovasc J Afr
November 2020
Department of Cardiology, Medical Faculty, Istanbul University, Istanbul, Turkey. Email:
Background: Pulmonary arterial hypertension (PAH) is a haemodynamic and pathophysiological condition with restricted flow through the pulmonary arterial circulation. In pulmonary hypertension, right ventricular hypertrophy and diastolic dysfunction can lead to an increase in atrial strain, fibrosis and dilation, which cause inhomogeneous atrial conduction. Interlead variation in P-wave duration is called P-wave dispersion (PwD), which is an electrocardiographic parameter that can be used to predict atrial arrhythmias.
View Article and Find Full Text PDFOpen Heart
February 2021
Department of Cardiology, Center for Cardiological Innovation, Oslo University Hospital, Rikshospitalet, Oslo, Norway.
Background: Patient-specific left ventricular (LV) lead optimisation strategies with immediate feedback on cardiac resynchronisation therapy (CRT) effectiveness are needed. The purpose of this study was to compare contractility surrogates derived from biventricular lead motion analysis to the peak positive time derivative of LV pressure (dP/dt in patients undergoing CRT implantation.
Methods: Twenty-seven patients underwent CRT implantation with continuous haemodynamic monitoring.
Arch Cardiovasc Dis
November 2017
Cardiology Department, François Rabelais University, Tours, France.
Background: Approximately one-third of patients do not respond favourably to cardiac resynchronization therapy (CRT). A longer distance between ventricular leads may improve response.
Aim: To study the impact of the true three-dimensional interlead distance (ILD) on outcomes.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!