A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel validated ultra-performance liquid chromatography Method for separation of eszopiclone impurities and its degradants in drug products. | LitMetric

A novel validated ultra-performance liquid chromatography Method for separation of eszopiclone impurities and its degradants in drug products.

J AOAC Int

Dr. Reddy's Laboratories Ltd IPDO, Bachupally, Hyderabad-500090, A.P, India, and J.N.T. University, Department of Chemistry, Kukatpally, Hyderabad-500085, A.P, India.

Published: January 2014

A selective, specific, and sensitive ultra-performance LC (UPLC) method was developed for determination of eszopiclone and its degradation products. The chromatographic separation was performed with a Waters ACQUITY UPLC system and BEH C18 column using gradient elution with mobile phases A and B. Mobile phase A was 0.01 M phosphate buffer with 0.2% (w/v) 1-octane sulfonic acid sodium salt as an ion pair reagent, adjusted pH 2.2 with orthophosphoric acid-acetonitrile (85 + 15, v/v). Mobile phase B was pH 2.2 buffer-acetonitrile (20 + 80, v/v). UV detection was performed at 303 nm. Eszopiclone and its impurities were chromatographed with a total run time of 13 min. A calibration study showed that the response for each of the impurities A, B, C, and D was linear between concentrations of 0.02 and 7.2 microg/mL (r2 > or = 0.999). The method was validated over this range for precision, intermediate precision, accuracy, linearity, and specificity. For the precision study, RSD of each impurity was <5% (n = 6). The method was found to be precise, accurate, linear, and specific. The proposed method was successfully used for determination of eszopiclone impurities in pharmaceutical preparations.

Download full-text PDF

Source
http://dx.doi.org/10.5740/jaoacint.11-489DOI Listing

Publication Analysis

Top Keywords

eszopiclone impurities
8
mobile phase
8
novel validated
4
validated ultra-performance
4
ultra-performance liquid
4
liquid chromatography
4
chromatography method
4
method separation
4
separation eszopiclone
4
impurities degradants
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!