Purpose: This study describes the use of an innovative dynamic implant valve approach (DIVA) for dental implant placement and sinus augmentation procedures.

Materials And Methods: The DIVA implant system was tested in vitro for leakage and mechanical fatigue. A closed sinus elevation procedure with a gel-type bone substitute was performed using the DIVA implant in a swine model (n = 6). Implants were placed and evaluated radiographically and histologically.

Results: Elevation of the maxillary sinus membrane and augmentation were performed in a simple, minimally invasive fashion. Histologic analyses demonstrated complete sealing of the DIVA implant and excellent osseointegration.

Conclusion: The DIVA can be used as a simplified viable option for dental implantation and augmentation procedures. Hermetic sealing of this implant system, which features an inner screw, renders it safe.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.te36DOI Listing

Publication Analysis

Top Keywords

implant system
12
diva implant
12
dental implant
8
closed sinus
8
sinus augmentation
8
implant
7
diva
5
novel dental
4
system internal
4
internal port
4

Similar Publications

The primary weight-bearing structure of the proximal femur, trabecular bone, has a complex three-dimensional architecture that was previously difficult to comprehensively display. This study examined the spatial architecture of trabecular struts in the coronal, sagittal, and horizontal sections of the proximal femur using 21 cases prepared with P45 sectional plasticization. The primary compressive strut (PCS) exhibited a "mushroom-like" shape with upper and lower parts.

View Article and Find Full Text PDF

Biodegradable polymeric microsphere formulations of full-length anti-VEGF antibody bevacizumab for sustained intraocular delivery.

Drug Deliv Transl Res

January 2025

Department of Pharmaceutical Sciences, School of Pharmacy and Pharmaceutical Sciences, Northeastern University, Boston, MA, 02115, USA.

Age-related macular degeneration (AMD) is one of the leading causes of central vision loss in the elderly population. Bevacizumab, a full-length humanized monoclonal anti-VEGF antibody, is commonly used off-label drug to treat AMD. However, the dosing regimen of bevacizumab and other anti-VEGF antibodies requires monthly intravitreal injections followed by regular intravitreal injections at 4-16-week intervals.

View Article and Find Full Text PDF

Surgical site infections (SSIs) following spinal instrumentation surgery are among the most concerning complications. This study is aimed at assessing the effectiveness of a new treatment approach for SSIs that includes a single-stage approach with the removal of the previous hardware, accurate debridement, and single-stage instrumentation using a silver fixation system (SFS) made of titanium alloy coated with silver (Norm Medical, Ankara, Turkey) by means of a retrospective observational study. The demographic data, type of surgery, comorbidities, pathogens, and treatment details of consecutive patients with an SSI who received the SFS between 2018 and 2021 were extracted from their medical records and analyzed.

View Article and Find Full Text PDF

Analysis of the Feasibility of the OrthoNail Hybrid Intramedullary Implant in the Human Body with Respect to Material Durability.

J Funct Biomater

January 2025

Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Smoluchowskiego 25, 50-372 Wrocław, Poland.

This study focuses on the development and evaluation of the OrthoNail hybrid intramedullary implant for lower limb lengthening in patients requiring significant skeletal reconstruction. The implant addresses the challenges in load-bearing during rehabilitation, providing a robust solution that is capable of supporting physiological loads. Mechanical tests, including axial compression, tension, torsion, and 3,4-point bending, determined the implant's load capacity and fatigue resistance, while finite element analysis assessed stress distributions in bone tissue and around screw holes during single-leg stance, with boundary conditions derived from Orthoload database data.

View Article and Find Full Text PDF

The widely available options of different manufacturers in dental implant systems have complicated the selection criteria process for periodontists, necessitating careful consideration of various factors when selecting suitable solutions for individual patient needs. Optimal implant selection requires careful consideration of the patient-specific factors, implant design, and surgical technique. Understanding the biomechanical behavior of implant-tissue interactions is crucial for achieving successful and long-lasting implant therapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!