The effect of continuous humidifier use on the bioaerosol concentration in an indoor environment was investigated. An ultrasonic humidifier was operated for 10 hr per day for 15 days in an apartment room. During this time period, viable bioaerosol samples were taken using a single-stage Andersen sampler containing culture media plates for bacteria and fungi. The culture plates were then incubated at room temperature for 2~7 days depending on the media. The counts for the air sample plates were corrected for multiple impactions using the positive hole conversion method and are reported as the colony forming units per cubic meter of air (CFU/m(3)). While the bacterial concentration measured using the tryptic soy agar (TSA) did not show any significant change during the first 3 days, the concentration increased from the 6(th) day (6979 CFU/m(3)) and reached a maximum on the 9(th) day (46431 CFU/m(3)). The concentration then decreased to 2470 CFU/m(3) on the 12(th) day, at which point the fungal concentration increased rapidly to 14424~16038 CFU/m(3). Also, while the fungal concentration showed a significant change until the 9(th) day of humidifier use, fungal growth was observed on the wallpaper and increased rapidly from the 12(th) day. However, the bacterial concentration increased rapidly after the fungi were removed by remediation. The major fungal species identified in the samples were Penicillium representing 34%, Aspergillus representing 31%, Cladosporium representing 24%, and Alternaria representing 1%. The results also indicated that a relative humidity over 80% was easily achieved with continuous humidifier use. Yet, maintaining a high humidity in a room can cause a rapid outbreak of microbial growth.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3834414 | PMC |
http://dx.doi.org/10.5487/TR.2012.28.2.103 | DOI Listing |
ACS Omega
January 2025
Department of Chemical and Biological Engineering, The University of British Columbia, 2360 East Mall, Vancouver V6T 1Z3, Canada.
The electrochemical carbon dioxide reduction reaction (CORR) using renewable electricity sources could provide a sustainable solution for generating valuable chemicals, such as formate salt or formic acid. However, an efficient, stable, and scalable electrode generating formate at industrially viable current densities (>100 mA cm) is yet to be developed. Sn or In-based catalysts in gas diffusion electrodes (GDE) can efficiently produce formate.
View Article and Find Full Text PDFJ Intensive Med
October 2024
Intensive Care Unit, Hospital Morales Meseguer, Murcia, Spain.
Recently, there has been growing interest in knowing the best hygrometry level during high-flow nasal oxygen and non-invasive ventilation (NIV) and its potential influence on the outcome. Various studies have shown that breathing cold and dry air results in excessive water loss by nasal mucosa, reduced mucociliary clearance, increased airway resistance, reduced epithelial cell function, increased inflammation, sloughing of tracheal epithelium, and submucosal inflammation. With the Coronavirus Disease 2019 pandemic, using high-flow nasal oxygen with a heated humidifier has become an emerging form of non-invasive support among clinicians.
View Article and Find Full Text PDFJ Paediatr Child Health
January 2025
Department of Paediatric Medicine, Townsville University Hospital, Townsville, Queensland, Australia.
Objective: To study the demographic characteristics, risk factors, management details and clinical outcomes to 12 months corrected age in indigenous and non-indigenous infants with chronic neonatal lung disease in North Queensland.
Design: Retrospective cohort study of infants with chronic neonatal lung disease admitted to a tertiary neonatal intensive care unit in regional Queensland from January 2015 to December 2019.
Results: There were 139 infants with chronic neonatal lung disease and 425 controls.
Eur J Pediatr
January 2025
Department of Women and Children's Health, School of Life Course Sciences, Faculty of Life Sciences and Medicine, King's College London, Denmark Hill, London, UK.
Unlabelled: Infants requiring interhospital transfer for a higher level of care in the neonatal period are at increased risk of adverse outcomes. Optimising respiratory management is an important priority. The aim of this survey was to investigate current respiratory support strategies in neonatal transport and identify opportunities for the optimisation of clinical care and future research.
View Article and Find Full Text PDFPlant Dis
December 2024
The Ohio State University, Plant Pathology, 2021 Coffey Road, Columbus, Ohio, United States, 43210;
, commonly known as stock, is a flowering plant species in the Brassicaceae popularly used as a cut flower due to its fragrant, long-lasting blooms. In September 2023, stock 'Iron White' plants displaying symptoms and signs of downy mildew were observed within a high tunnel in a cut flower farm in Franklin Co., OH.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!