In the framework of the NESCOFI@BTF project of the Italian Institute of Nuclear Physics, different types of active thermal neutron sensors were studied by coupling semiconductor devices with a suitable radiator. The objective was to develop a detector of small dimensions with a proper sensitivity to use at different positions in a novel moderating assembly for neutron spectrometry. This work discusses the experimental activity carried out in the framework of the ERINDA program (PAC 3/9 2012) to characterise the performance of a thermal neutron pulse detector based on (6)Li.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/nct298DOI Listing

Publication Analysis

Top Keywords

thermal neutron
12
neutron sensors
8
neutron
5
compact thermal
4
sensors moderator-based
4
moderator-based neutron
4
neutron spectrometers
4
spectrometers framework
4
framework nescofi@btf
4
nescofi@btf project
4

Similar Publications

Insights into the electroactive impact of magnetic nanostructures in PVDF composites small-angle neutron scattering.

Nanoscale

January 2025

Physics Centre of Minho and Porto Universities (CF-UM-UP) and LaPMET - Laboratory of Physics for Materials and Emergent Technologies, University of Minho, 4710-057 Braga, Portugal.

Poly(vinylidene fluoride) (PVDF) is technologically relevant due to its thermal stability; chemical, mechanical and radiation resistance; transparency; biocompatibility; and ease of processing. Several of those applications are related to its high electroactivity, for which the β-phase of the polymer is its most renowned protagonist. In this context, extensive research has been conducted on the crystallization of PVDF in the β-phase, when processed from melt and from solution.

View Article and Find Full Text PDF

H*10 neutron dosimetry (unlike gamma dosimetry), requires consideration of neutron energy spectra due to the 20× variation of the weight factor over the thermal-to-fast energy range, as well as the neutron radiation field dose rates ranging from cosmic, ~.01 μSv h-1 levels to commonly encountered ~10-200 μSv h-1 in nuclear laboratories/processing plants, and upwards of 104 Sv h-1 in nuclear reactor environments. This paper discusses the outcome of the comparison of spectrum-weighted neutron dosimetry covering thermal-to-fast energy using the novel H*-TMFD spectroscopy-enabled sensor system in comparison with measurements using state-of-the-art neutron dosimetry systems at SRNS-Rotating Spectrometer (ROSPEC), and non-spectroscopic Eberline ASP2E ("Eberline") and Ludlum 42-49B ("Ludlum") survey instrumentation.

View Article and Find Full Text PDF

A Manufacturing Technique for Binary Clathrate Hydrates for Cold and Very Cold Neutron Production.

Materials (Basel)

January 2025

Institut Laue-Langevin (ILL), 71 Avenue des Martyrs, 38042 Grenoble Cedex 9, France.

Intense sources of very cold neutrons (VCNs) would be beneficial for various neutron scattering techniques and low-energy particle physics experiments. Binary clathrate hydrates hosting deuterated tetrahydrofuran (THF-d) and dioxygen show promise as potential moderators for such sources due to a rich spectrum of localized low-energy excitations of the encaged guest molecules. In this article, we present a reliable manufacturing technique for such hydrates.

View Article and Find Full Text PDF

To push upper boundaries of thermal conductivity in polymer composites, understanding of thermal transport mechanisms is crucial. Despite extensive simulations, systematic experimental investigation on thermal transport in polymer composites is limited. To better understand thermal transport processes, we design polymer composites with perfect fillers (graphite) and defective fillers (graphite oxide), using polyvinyl alcohol (PVA) as a matrix model.

View Article and Find Full Text PDF

Any experiment aiming to measure rare events, like Coherent Elastic neutrino-Nucleus Scattering (CE NS) or hypothetical Dark Matter scattering, via nuclear recoils in cryogenic detectors relies crucially on a precise detector calibration at sub-keV energies. The Crab collaboration developed a new calibration technique based on the capture of thermal neutrons inside the target crystal. Together with the Nucleus experiment, first measurements with a moderated Cf neutron source and a cryogenic detector were taken.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!