There is a general agreement that the most valid method of measuring peak lower-body mechanical power output (LBPP) in a countermovement jump (CMJ) is by analysis of the corresponding vertical component of the ground reaction force (VGRF)-time history of the jump. However, there is no published standard protocol. The purpose of this study was to establish a standard protocol. The variables necessary to define a valid and reliable CMJ method were: (a) vertical force range, (b) force sampling and integration frequency, (c) method of integration, (d) determination of body weight (BW), and (e) determination of the initiation of the CMJ. Countermovement jumps off a force platform (FP) were performed by 15 male professional rugby players. The 5 variables were then optimized to maximize the reliability and validity of the measure of LBPP. Errors of <1% (p ≤ 0.05) in the measurement of LBPP were obtained using the following specification: (a) 6 times BW (using a 16-bit analog to digital converter), (b) 1,000 Hz, (c) Simpson's rule or the trapezoidal rule, (d) mean VGRF for 1 second of quiet standing immediately before jump signal, and (e) 30 ms before the instant BW ± 5 SD is exceeded after the jump signal. Peak lower-body power output was most sensitive to variables 4 and 5. It was concluded that this study has established a standard protocol for the criterion method of measuring peak power in a CMJ using an FP. As all other estimates and less reliable methods of determining LBPP in a CMJ rely on the FP method for calibration, it is proposed that this protocol be used as the basis of future criterion measures using a FP.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1519/JSC.0000000000000311 | DOI Listing |
Chemistry
January 2025
University of Hyderabad School of Chemistry, School of Chemistry, School of Chemistry, University of Hyderabad, 500046, Hyderabad, INDIA.
The amorphous/crystalline (A/C) assembly in molecular solids has a direct bearing on their attributes and applications, including mechanical, pharmaceutical, electronic and photophysical. A systematic analysis of the molecular features and interactions that determine the predilection towards the A, C or bi-stable A-C states is critical. This fundamental problem is addressed through an exhaustive investigation of a large family of alkoxyalkyl diaminodicyanoquinodimethanes (ROR'-DADQs); enhancement of their fluorescence from the solution, to the A, to the C state serves as an excellent signature of the phase preference and temporal stability.
View Article and Find Full Text PDFMater Today Bio
February 2025
Discipline of Mechanical, Manufacturing and Biomedical Engineering, School of Engineering, Trinity College Dublin, Dublin 2, Ireland.
Peripheral nerve repair (PNR) is a major healthcare challenge due to the limited regenerative capacity of the nervous system, often leading to severe functional impairments. While nerve autografts are the gold standard, their implications are constrained by issues such as donor site morbidity and limited availability, necessitating innovative alternatives like nerve guidance conduits (NGCs). However, the inherently slow nerve growth rate (∼1 mm/day) and prolonged neuroinflammation, delay recovery even with the use of passive (no-conductive) NGCs, resulting in muscle atrophy and loss of locomotor function.
View Article and Find Full Text PDFBiomed Opt Express
January 2025
Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA.
Deep-UV microscopy enables high-resolution, label-free molecular imaging by leveraging biomolecular absorption properties in the UV spectrum. Recent advances in UV-imaging hardware have renewed interest in this technique for quantitative live cell imaging applications. However, UV-induced photodamage remains a concern for longitudinal dynamic imaging studies.
View Article and Find Full Text PDFWater Sci Technol
January 2025
Department of Production Engineering and Mechanical Design, Faculty of Engineering, Tanta University 31527, Egypt; Faculty of Engineering, Pharos University in Alexandria 21648, Alexandria, Egypt.
This review examines the potential for utilizing nuclear power plant (NPP) waste heat in hybrid desalination systems, focusing on Reverse Osmosis-Low-Temperature Evaporation (RO-LTE) driven by renewable energy sources and atomic waste heat. By employing a SOAR (Strengths, Opportunities, Aspirations, Results) analysis, the study evaluates the integration of NPP waste heat into various desalination technologies, emphasizing the environmental benefits and energy efficiency improvements. Fundamental aspirations include advancements in material science and heat exchanger designs, which enhance heat transfer and evaporation processes.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Excellence Center for Hip & Knee Arthroplasty, Department of Orthopedic Surgery, Zuyderland Medical Center, Heerlen, The Netherlands.
Introduction: In 2020, 368 million people globally were affected by knee osteoarthritis, and prevalence is projected to increase with 74% by 2050. Relatively high rates of dissatisfactory results after total knee arthroplasty (TKA), as reported by approximately 20% of patients, may be caused by sub-optimal knee alignment and balancing. While mechanical alignment has traditionally been the goal, patient-specific alignment strategies are gaining interest.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!