Recurrent implantation failure refers to failure to achieve a clinical pregnancy after transfer of at least four good-quality embryos in a minimum of three fresh or frozen cycles in a woman under the age of 40 years. The failure to implant may be a consequence of embryo or uterine factors. Thorough investigations should be carried out to ascertain whether there is any underlying cause of the condition. Ovarian function should be assessed by measurement of antral follicle count, FSH and anti-Mu¨llerian hormone. Increased sperm DNA fragmentation may be a contributory cause. Various uterine pathology including fibroids, endometrial polyps, congenital anomalies and intrauterine adhesions should be excluded by ultrasonography and hysteroscopy. Hydrosalpinges are a recognized cause of implantation failure and should be excluded by hysterosalpingogram; if necessary, laparoscopy should be performed to confirm or refute the diagnosis. Treatment offered should be evidence based, aimed at improving embryo quality or endometrial receptivity. Gamete donation or surrogacy may be necessary if there is no realistic chance of success with further IVF attempts.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.rbmo.2013.08.011 | DOI Listing |
Int J Mol Sci
December 2024
College of Animal Science and Technology, Northeast Agricultural University, Harbin 150038, China.
Uterine infections reduce ruminant reproductive efficiency. Reproductive dysfunction caused by infusion of Gram-negative bacteria is characterized by the failure of embryo implantation and reduced conception rates. Lipopolysaccharide (LPS), a major component of the outer membrane of Gram-negative bacteria, is highly abortogenic.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Biotechnology Center, The Silesian University of Technology, 44-100 Gliwice, Poland.
Biomimetic natural biomaterial (BNBM) nanocomposite scaffolds for bone replacement can reduce the rate of implant failure and the associated risks of post-surgical complications for patients. Traditional bone implants, like allografts, and autografts, have limitations, such as donor site morbidity and potential patient inflammation. Over two million bone transplant procedures are performed yearly, and success varies depending on the material used.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Autoimmune Diseases, Reference Centre for Systemic Autoimmune Diseases (UEC/CSUR) of the Catalan and Spanish Health Systems-Member of ERNReCONNET, Hospital Clínic, University of Barcelona, 08036 Barcelona, Catalonia, Spain.
: The clinical and laboratory features of patients with non-criteria obstetric antiphospholipid syndrome (NC-OAPS), as well as their pregnancy outcomes and ideal treatment are not clearly determined. The aim of this study is to describe the characteristics and outcomes of pregnancies in NC-OAPS and compare them with an obstetric APS (OAPS) cohort. : This is a retrospective study conducted on a cohort of women referred to a high-risk obstetric unit of a tertiary hospital.
View Article and Find Full Text PDFJ Clin Med
December 2024
Second Department of Internal Medicine, "Victor Babes" University of Medicine and Pharmacy, 300041 Timisoara, Romania.
Cardio-renal syndrome (CRS) is a complex condition involving bidirectional dysfunction of the heart and kidneys, in which the failure of one organ exacerbates failure in the other. Traditional pharmacologic treatments are often insufficient to manage the hemodynamic and neurohormonal abnormalities underlying CRS, especially in cases resistant to standard therapies. Device-based therapies have emerged as a promising adjunct or alternative approach, offering targeted intervention to relieve congestion, improve renal perfusion, and modulate hemodynamics.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Cardiology and Electrotherapy, Faculty of Medicine, Medical University of Gdansk, 80-210 Gdansk, Poland.
A leadless pacemaker (LP) is a modern alternative to a transvenous pacemaker, allowing certain complications to be avoided; however, some cannot be eliminated. To highlight the essential role of advanced speckle-tracking echocardiography (STE) in diagnosing pacing-induced cardiomyopathy (PICM) caused by an LP. A 79-year-old male, after LP implantation a year earlier, was admitted due to heart failure (HF).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!