Background: Different iterative reconstruction (IR) techniques compensate increased noise from lower tube current-time product settings, yet the differences between IR settings remain unclear.

Objective: Aim of this study was to test whether different IR settings have a clinically relevant influence on image quality and on the diagnostic accuracy of low-dose CT angiography in patients with a stent.

Methods: Forty-two patients with 73 coronary stents were prospectively enrolled. Data were acquired with dual-source CT, and images were reconstructed with standard filtered back projection (FBP) and raw data-based IR with different settings (I3, I4, I5). Quantitative parameters, including CT-attenuation, noise, signal-to-noise ratio, contrast-to-noise ratio, as well as the presence of in-stent stenosis > 50% were determined. All patients had invasive angiography as reference standard.

Results: Mean effective dose was 0.32 ± 0.02 mSv. Image noise decreased significantly compared with FBP (I3 = 29%; I4 = 38% and I5 = 45%), whereas signal-to-noise and contrast-to-noise ratios increased significantly (all IR settings P < .01). Subjective image quality was superior with all IR settings (P < .01). FBP sensitivity, specificity, positive predictive value, and negative predictive value were 83%, 71%, 36%, and 96% per stent compared with 100%, 76%, 44%, and 100%, respectively, in IR reconstructions independent of the IR setting applied.

Conclusion: In low-dose coronary CT angiography, higher IR settings significantly improved subjective and objective image quality but had no effect on accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcct.2013.08.012DOI Listing

Publication Analysis

Top Keywords

image quality
12
low-dose coronary
8
coronary angiography
8
iterative reconstruction
8
settings
8
stent evaluation
4
evaluation low-dose
4
angiography
4
angiography iterative
4
reconstruction settings
4

Similar Publications

Importance: In the Atrial Cardiopathy and Antithrombotic Drugs in Prevention After Cryptogenic Stroke (ARCADIA) randomized clinical trial, anticoagulation did not prevent recurrent stroke among patients with a recent cryptogenic stroke and atrial cardiopathy. It is unknown whether anticoagulation prevents covert infarcts in this population.

Objective: To test the use of apixaban vs aspirin for prevention of nonlacunar covert infarcts after cryptogenic stroke in patients with atrial cardiopathy.

View Article and Find Full Text PDF

Fast, Present and Future of the Concept of Spondyloarthritis.

Curr Rheumatol Rep

January 2025

Rheumatologisches Versorgungszentrum Steglitz, Ruhr Universität Bochum, Schloßstr.110, 12163, Berlin, Germany.

Purpose Of Review: Axial spondyloarthritis (axSpA) is a rather prevalent chronic inflammatory rheumatic disease that affects already relatively young patients. It has been known better since the end of the nineteenth century but quite a lot has been learned since the early 60ies when the first classification (diagnostic) criteria for ankylosing spondylitis (AS) were agreed on. I have been part of many developments in the last 30 years, and I'm happy to have been able to contribute to the scientific progress in terms of diagnosis, imaging, pathophysiology and therapy.

View Article and Find Full Text PDF

[Indications for surgical treatment of traumatic fractures of the thoracic spine and lumbar spine].

Unfallchirurgie (Heidelb)

January 2025

Klinik für Orthopädie, Unfallchirurgie und Plastische Chirurgie, Universitätsklinikum Leipzig AöR, Liebigstraße 20, 04103, Leipzig, Deutschland.

Fractures of the thoracic (Th) and lumbar (L) vertebrae are among the most frequent fracture entities in Germany and particularly affect the thoracolumbar junction (TLJ; Th11-L2). Based on expert recommendations and consensus meetings, the thoracolumbar AOSpine injury score was established for patients with healthy bone and the osteoporotic fracture (OF) score for geriatric patients with the respective classifications for treatment decisions. In both cohorts, the treatment decision is based on the fracture morphology, neurological status and patient-specific contextual factors.

View Article and Find Full Text PDF

Purpose: The depth within the body, small diameter, long length, and varying tissue surrounding the spinal cord impose specific considerations when designing radiofrequency coils. The optimal coil configuration for 7 T cervical spinal cord MRI is unknown and, currently, there are very few coil options. The purpose of this work was (1) to establish a quality control protocol for evaluating 7 T cervical spinal cord coils and (2) to use that protocol to evaluate the performance of 4 different coil designs.

View Article and Find Full Text PDF

The quality of CT images obtained from hepatocellular carcinoma (HCC) patients is complex, affecting diagnostic accuracy, precision, and radiation dose assessment due to increased exposure risks. The study evaluated image quality qualitatively and quantitatively by comparing quality levels with an effective radiation dose to ensure acceptable quality accuracy. This study retrospectively reviewed 100 known HCC patients (Li-RADS-5) who underwent multidetector computed tomography (MDCT) multiphasic scans for follow-up of their health condition between January and October 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!