Objective: To compare biomechanical effect of the closed fracture model with intramedullary nail fixation and the open fracture model with plate fixation in rats.

Methods: Forty 8-week-old Spragu-Dawley male rats were divided into two groups randomly. Left femoral shaft closed fractures model was created in 20 rats, and treated with intramedullary nail. Other 20 rats received open osteotomy on the left femoral shaft, and were fixed by plate. Rats were sacrificed and draw the materials at 4, 6, 8 and 12 weeks in batch. Across section area and volume of callus were measured, peak load, restoration rate of peak load were tested. The biomechanical efficency of two methods of femoral shaft fracture fixation were compared.

Results: The difference of surgical duration was statistically significant between two groups (P < 0.001). At 4, 6, 8 and 12 weeks, the difference of peak load, restoration rate of peak load, volume and area of callus was also statistically significant between two groups (P < 0.05).

Conclusion: Open fracture model with plate fixation led to delayed healing compared with closed fracture model with intramedullary nail. However, open fracture model with plate fixation model could be a valuable research tool to study the healing consequences of cortical bone, which may provide insight into the pathogenesis and ideal treatment of fractures or nonunions.

Download full-text PDF

Source

Publication Analysis

Top Keywords

fracture model
28
open fracture
16
model plate
16
plate fixation
16
intramedullary nail
16
peak load
16
closed fracture
12
model intramedullary
12
femoral shaft
12
model
9

Similar Publications

Rib pathology is uniquely difficult and time-consuming for radiologists to diagnose. AI can reduce radiologist workload and serve as a tool to improve accurate diagnosis. To date, no reviews have been performed synthesizing identification of rib fracture data on AI and its diagnostic performance on X-ray and CT scans of rib fractures and its comparison to physicians.

View Article and Find Full Text PDF

Objective: Accurate rotational reduction following tibial shaft fracture fixation is absent in up to 36% of cases yet may be critical for lower extremity biomechanics. The objective of this cadaveric study was to compare the results of freehand methods of reduction with software-assisted reduction.

Methods: Four fellowship-trained orthopaedic trauma surgeons attempted rotational correction in a cadaveric model with fluoroscopic assistance (without radiographic visualization of the fracture site) using (1) their method of choice (MoC) and (2) software assistance (SA).

View Article and Find Full Text PDF

Prediction of hip fracture by high-resolution peripheral quantitative computed tomography in older Swedish women.

J Bone Miner Res

January 2025

Sahlgrenska Osteoporosis Centre, Department of Internal Medicine and Clinical Nutrition, Institute of Medicine, University of Gothenburg, Gothenburg, Sweden.

The socioeconomic burden of hip fractures, the most severe osteoporotic fracture outcome, is increasing and the current clinical risk assessment lacks sensitivity. This study aimed to develop a method for improved prediction of hip fracture by incorporating measurements of bone microstructure and composition derived from high-resolution peripheral quantitative computed tomography (HR-pQCT). In a prospective cohort study of 3028 community-dwelling women aged 75 to 80, all participants answered questionnaires and underwent baseline examinations of anthropometrics and bone by dual x-ray absorptiometry (DXA) and HR-pQCT.

View Article and Find Full Text PDF

Background: Ankle fractures continue to increase in incidence and severity in an older, more challenging geriatric population. Medial malleolus fixation with partially threaded cancellous 4.0-mm screws, a common fixation method, has been shown to fail due to pullout strength.

View Article and Find Full Text PDF

Background: The spinal column is a frequent site for metastases, affecting over 30% of solid tumor patients. Identifying the primary tumor is essential for guiding clinical decisions but often requires resource-intensive diagnostics.

Purpose: To develop and validate artificial intelligence (AI) models using noncontrast MRI to identify primary sites of spinal metastases, aiming to enhance diagnostic efficiency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!