M-mode and 2-dimensional (2D) echocardiographic imaging are routinely used to quantify left-ventricular (LV) size and function in pediatric patients with dilated cardiomyopathy (DCM). The reproducibility of and correlation between these techniques are unknown. This analysis sought to compare interreader, intrareader, and interacquisition reproducibility of M-mode versus 2D measurements in pediatric DCM patients. The Ventricular Volume Variability study of the Pediatric Heart Network is a multicenter, prospective, observational study assessing the course of chronic DCM in children. Two sonographers performed baseline image acquisitions locally, and two readers performed measurements at the echocardiographic core laboratory. One reader repeated measurements 1 month later. These data were used to assess reproducibility and agreement between M-mode and 2D measurements. One hundred sixty-nine subjects were enrolled. M-mode had similar or greater reproducibility in both intrareader and interreader settings for LV dimensions, shortening fraction (SF), and most wall thicknesses. In contrast, 2D reproducibility was similar or better for nearly all variables in the interacquisition setting but not for SF. Interacquisition variability was approximately twice the intrareader variability. LV dimensions by either modality consistently had high reproducibility and had the highest agreement between modalities. In pediatric DCM patients, variability of linear echocardiographic assessment could be minimized by relying on a single reader and using a consistent method (M-mode or 2D) for serial measurements, preferably M-mode when SF is the primary variable of interest. Except for LV dimensions, M-mode and 2D values should not be used interchangeably due to poor agreement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4681428PMC
http://dx.doi.org/10.1007/s00246-013-0835-9DOI Listing

Publication Analysis

Top Keywords

m-mode versus
8
dilated cardiomyopathy
8
pediatric dcm
8
dcm patients
8
m-mode
7
measurements
6
reproducibility
6
variability
5
variability m-mode
4
versus two-dimensional
4

Similar Publications

Article Synopsis
  • Endomyocardial biopsy is the standard method for monitoring heart transplant rejection, but this study explored a non-invasive index for assessing left ventricular relaxation in pediatric patients.
  • The researchers analyzed data from 65 pediatric heart transplant patients who underwent 246 procedures to compare the new left ventricular relaxation index with traditional biopsy results for detecting cellular rejection.
  • The findings showed that while the index had good sensitivity (100%) for identifying higher grades of rejection (2R and 3R), it lacked specificity (23%), indicating it may not be a reliable predictor of cardiac rejection in these patients.
View Article and Find Full Text PDF

Preferential activation of rectus abdominis sections during crunch or leg lifts has long been disputed. The objectives of this study were to both explore the activation of the rectus abdominis during these exercises. This study used a randomised independent measures design utilising both EMG and diagnostic ultrasound to record changes in rectus abdominis activity.

View Article and Find Full Text PDF

Background: Impairment of left ventricular (LV) longitudinal function is an early marker of systolic dysfunction in hypertrophic cardiomyopathy (HCM). Aortic annular plane systolic excursion (AAPSE) is a measure of LV longitudinal function in people that has not been evaluated in cats.

Hypothesis: Aortic annular plane systolic excursion is lower in cats with HCM compared to control cats, and cats in stage C have the lowest AAPSE.

View Article and Find Full Text PDF

Evaluation of the Breastfeeding Dynamics of Neonates with Ankyloglossia via a Novel Ultrasonographic Technique.

Diagnostics (Basel)

November 2023

Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara 06560, Türkiye.

To effectively address breastfeeding issues for neonates and mothers, one must understand the physiology of breastfeeding and the anatomical components involved in sucking, swallowing, and respiration. This study compared the tongue position and movement of neonates with tongue ties versus healthy controls during sucking. A new objective ultrasonography diagnostic approach was also introduced for the orofacial region.

View Article and Find Full Text PDF

Echocardiography is the most widely accepted diagnostic tool for assessment of cardiac function and morphology in dogs and is usually performed in lateral recumbency. However, in some situations or in stressed patients, it is necessary to perform it in a standing position. Only one study evaluated the effects of animal position on selected two-dimensional and M-mode echocardiographic variables in four healthy dogs of different breeds, but not in brachycephalic breeds.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!