Introduction: In this study we aimed to develop a simple and practical technique for chronic sacral epidural catheterization of rabbits.
Methods: We included ten rabbits weighing 2-2.5 kg in the study. After anesthesia and analgesia, we placed an epidural catheter by a 2 cm longitudinal skin incision in the tail above the sacral hiatus region. We confirmed localization by giving 1% lidocaine (leveling sensory loss and motor function loss of the lower extremity). The catheter was carried forward through a subcutaneous tunnel and fixed at the neck.
Results: Chronic caudal epidural catheter placement was succesful in all rabbits. The catheters stayed in place effectively for ten days. We encountered no catheter complications during this period. The localization of the catheter was reconfirmed by 1% lidocaine on the last day. After animals killing, we performed a laminectomy and verified localization of the catheter in the epidural space.
Conclusions: Various methods for catheterization of the epidural space in animal models exist in the literature. Epidural catheterization of rabbits can be accomplished by atlanto-occipital, lumbar or caudal routes by amputation of the tail. Intrathecal and epidural catheterization techniques defined in the literature necessitate surgical skill and knowledge of surgical procedures like laminectomy and tail amputation. Our technique does not require substantial surgical skill, anatomical integrity is preserved and malposition of the catheter is not encountered. In conclusion, we suggest that our simple and easily applicable new epidural catheterization technique can be used as a model in experimental animal studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bjan.2012.10.001 | DOI Listing |
A A Pract
November 2024
From the Department of Anesthesiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois.
Thoracic epidural analgesia is commonly used for postoperative analgesia for abdominal and thoracic surgeries. One complication of thoracic epidural catheter placement is a malpositioned catheter, such as in the subarachnoid, subdural, or intrapleural space. We present a case of unintentional posterior mediastinal catheter placement.
View Article and Find Full Text PDFActa Anaesthesiol Scand
January 2025
Department of Anaesthesiology and Intensive Care, University of Helsinki and Helsinki University Hospital, Helsinki, Finland.
Eur J Trauma Emerg Surg
December 2024
Department of Neurosurgery, Faculty of Medicine and Health, Örebro University, Örebro, Sweden.
Am J Obstet Gynecol MFM
December 2024
Department of Obstetrics and Gynaecology, Monash University, Faculty of Medicine, Nursing and Health Sciences, Monash Medical Centre, 246 Clayton Rd, Clayton, Victoria 3168 Australia (Seo, Davies-Tuck, Warty, Smith, and Palmer); Monash Women's, Monash Health, 246 Clayton Rd, Clayton, Victoria Australia (Palmer).
Anaesthesia
December 2024
Department of Anaesthesia, London North West University Healthcare NHS Trust, London, UK.
Background: Anaesthetists of all grades who work on a labour ward are likely to be involved in the insertion or management of an intrathecal catheter after inadvertent dural puncture at some point in their careers. Although the use of intrathecal catheters after inadvertent dural puncture in labour has increased in popularity over recent decades, robust evidence on best practice has been lacking.
Methods: The Obstetric Anaesthetists' Association set up an expert working party to review the literature.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!