A new technique for long time catheterization of sacral epidural canal in rabbits.

Braz J Anesthesiol

Departamento de Anestesiologia, Faculdade de Medicina, Dokuz Eylül University, İzmir, Turquia. Electronic address:

Published: April 2015

Introduction: In this study we aimed to develop a simple and practical technique for chronic sacral epidural catheterization of rabbits.

Methods: We included ten rabbits weighing 2-2.5 kg in the study. After anesthesia and analgesia, we placed an epidural catheter by a 2 cm longitudinal skin incision in the tail above the sacral hiatus region. We confirmed localization by giving 1% lidocaine (leveling sensory loss and motor function loss of the lower extremity). The catheter was carried forward through a subcutaneous tunnel and fixed at the neck.

Results: Chronic caudal epidural catheter placement was succesful in all rabbits. The catheters stayed in place effectively for ten days. We encountered no catheter complications during this period. The localization of the catheter was reconfirmed by 1% lidocaine on the last day. After animals killing, we performed a laminectomy and verified localization of the catheter in the epidural space.

Conclusions: Various methods for catheterization of the epidural space in animal models exist in the literature. Epidural catheterization of rabbits can be accomplished by atlanto-occipital, lumbar or caudal routes by amputation of the tail. Intrathecal and epidural catheterization techniques defined in the literature necessitate surgical skill and knowledge of surgical procedures like laminectomy and tail amputation. Our technique does not require substantial surgical skill, anatomical integrity is preserved and malposition of the catheter is not encountered. In conclusion, we suggest that our simple and easily applicable new epidural catheterization technique can be used as a model in experimental animal studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bjan.2012.10.001DOI Listing

Publication Analysis

Top Keywords

epidural catheterization
16
epidural
9
sacral epidural
8
epidural catheter
8
localization catheter
8
surgical skill
8
catheter
7
catheterization
6
technique
4
technique long
4

Similar Publications

Thoracic epidural analgesia is commonly used for postoperative analgesia for abdominal and thoracic surgeries. One complication of thoracic epidural catheter placement is a malpositioned catheter, such as in the subarachnoid, subdural, or intrapleural space. We present a case of unintentional posterior mediastinal catheter placement.

View Article and Find Full Text PDF
Article Synopsis
  • The study compared the failure rates of epidural catheters used in combined spinal epidural (CSE) techniques against traditional epidural practices during labor, involving over 9,000 parturients.
  • Results indicated a higher failure rate for traditional epidurals (5.2%) compared to CSE (3.7%), but adjustments for factors like stage of labor and anesthesiologist experience showed similar rates.
  • CSE techniques were initiated earlier in labor and showed longer mean times until catheter failure (6.3 hours for CSE vs. 4.0 hours for traditional), with implications for better birth experiences.
View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to examine how total REBOA (tREBOA) affects cerebral blood flow and intracranial pressure (ICP) in pigs during controlled hemorrhagic shock and subsequent resuscitation.
  • Researchers used 22 anesthetized pigs, splitting them into two groups: one with elevated ICP (EICPG) and one with normal ICP (NICPG), and monitored their vital parameters before and after inducing shock.
  • Results showed that tREBOA effectively restored cerebral perfusion in both groups, even with periods of impaired autoregulation, confirming its potential as a lifesaving intervention during critical resuscitation scenarios.
View Article and Find Full Text PDF

Digital versus speculum-based balloon catheter insertion for labor induction: a systematic review and meta-analysis.

Am J Obstet Gynecol MFM

December 2024

Department of Obstetrics and Gynaecology, Monash University, Faculty of Medicine, Nursing and Health Sciences, Monash Medical Centre, 246 Clayton Rd, Clayton, Victoria 3168 Australia (Seo, Davies-Tuck, Warty, Smith, and Palmer); Monash Women's, Monash Health, 246 Clayton Rd, Clayton, Victoria Australia (Palmer).

Article Synopsis
  • The study examines the effectiveness, safety, and acceptability of two methods for cervical preparation prior to labor induction: digital insertion vs. speculum-based insertion of catheter balloons.
  • It utilized various medical databases to find randomized controlled trials that met specific criteria, focusing on viable singleton pregnancies and excluding studies that didn't involve cervical balloons.
  • The results indicated that while digital insertion was generally less painful and had comparable maternal satisfaction, overall outcomes showed no significant difference between the two methods, despite some concerns over study biases.
View Article and Find Full Text PDF

Background: Anaesthetists of all grades who work on a labour ward are likely to be involved in the insertion or management of an intrathecal catheter after inadvertent dural puncture at some point in their careers. Although the use of intrathecal catheters after inadvertent dural puncture in labour has increased in popularity over recent decades, robust evidence on best practice has been lacking.

Methods: The Obstetric Anaesthetists' Association set up an expert working party to review the literature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!