Capabilities of ultrasound biomicroscopy (UBM) as a diagnostic method for surgical planning and outcome analysis in nonstandard situations in phaco surgery have been investigated. The study enrolled 270 patients (278 eyes) with pseudophakia and 26 patients (33 eyes) with aphakia. The scanning was done on OTI HF 35-50 Ultrasound System biomicroscope (UBM) - OTI, Canada. An original method of intraocular lens (IOL) position evaluation by means of UBM, providing precise information on relative position of the IOL and ocular axes, planes, and anatomical structures, has been developed. The proposed technique has been applied to determine both whether the position of the IOL is correct (46 eyes) and, if not, which of three types of its dislocation is present (232 eyes). Clinical and functional features of each of the dislocation types have been analyzed. Detailed analysis of UBM scans of 47 patients (47 eyes) showed that secondary glaucoma development was triggered by loss of proper endocapsular fixation of the IOL with consequent traumatic contact between IOL haptics and uveal tract. This contact, on the one hand, leads to excessive wash-out of pigment and obstruction of outflow routes. On the other hand, it causes subacute reactive uveitis which aggravates preexisting ocular hypertension and glaucoma course. It has been demonstrated that UBM performed prior to IOL implantation enables adequate assessment of the implant bed, accounting for lens capsule integrity, ciliary sulcus configuration and parameters, as well as the extent of structural changes in the globe, which may result from trauma, uveitis or improper evacuation of lens matter during cataract removal. Authors recommend to include UBM into assessment of aphakic patients planned for secondary IOL implantation and to decide on IOL model and its fixation type depending on the UBM results.

Download full-text PDF

Source

Publication Analysis

Top Keywords

capabilities ultrasound
8
ultrasound biomicroscopy
8
patients eyes
8
iol
8
position iol
8
iol implantation
8
ubm
7
eyes
5
[diagnostic capabilities
4
biomicroscopy phaco
4

Similar Publications

A review of state-of-the-art resolution improvement techniques in SPECT imaging.

EJNMMI Phys

January 2025

Department of Nuclear Medicine, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, 230001, Anhui, China.

Single photon emission computed tomography (SPECT), a technique capable of capturing functional and molecular information, has been widely adopted in theranostics applications across various fields, including cardiology, neurology, and oncology. The spatial resolution of SPECT imaging is relatively poor, which poses a significant limitation, especially the visualization of small lesions. The main factors affecting the limited spatial resolution of SPECT include projection sampling techniques, hardware and software.

View Article and Find Full Text PDF

Purpose: Shear wave elastography (SWE) provides a means for adding information about the mechanical properties of tissues to a diagnostic ultrasound examination. It is important to understand the physics and methods by which the measurements are made to aid interpretation of the results as they relate to disease processes.

Methods: The components of how ultrasound is used to generate shear waves and make measurements of the induced motion are reviewed.

View Article and Find Full Text PDF

Background: He's team have recently developed a new Coronary Artery Tree description and Lesion EvaluaTion (CatLet) angiographic scoring system, which is capable of accounting for the variability in coronary anatomy, and risk-stratifying patients with coronary artery disease. Preliminary studies have demonstrated its superiority over the the Synergy between percutaneous coronary intervention with Taxus and Cardiac Surgery (SYNTAX) score with respect to outcome predictions for acute myocardial infarction (AMI) patients. However, there are fewer studies on the prognostic in chronic coronary artery disease(CAD).

View Article and Find Full Text PDF

Enhancing furcation involvement classification on panoramic radiographs with vision transformers.

BMC Oral Health

January 2025

Department of Periodontics, Affiliated Hospital of Medical School, Nanjing Stomatological Hospital, Research Institute of Stomatology, Nanjing University, Nanjing, China.

Background: The severity of furcation involvement (FI) directly affected tooth prognosis and influenced treatment approaches. However, assessing, diagnosing, and treating molars with FI was complicated by anatomical and morphological variations. Cone-beam computed tomography (CBCT) enhanced diagnostic accuracy for detecting FI and measuring furcation defects.

View Article and Find Full Text PDF

Objectives: This study aimed to develop a multimodal radiopathomics model utilising preoperative ultrasound (US) and fine-needle aspiration cytology (FNAC) to predict large-number cervical lymph node metastasis (CLNM) in patients with clinically lymph node-negative (cN0) papillary thyroid carcinoma (PTC).

Materials And Methods: This multicentre retrospective study included patients with PTC between October 2017 and June 2024 across seven institutions. Patients were categorised based on the presence or absence of large-number CLNM in training, validation, and external testing cohorts.

View Article and Find Full Text PDF