Assessment of lower extremity arterial blood flow in females with knee osteoarthritis.

Clin Rheumatol

Department of Physical Medicine and Rehabilitation, Harran University Medical School, Yenisehir Kampusu, 63100, Sanliurfa, Turkey,

Published: February 2015

AI Article Synopsis

Article Abstract

To investigate whether blood flow in the lower extremity arteries changes in patients with osteoarthritis (OA) using color Doppler ultrasonography. The study comprised 39 female patients with osteoarthritis and 30 healthy female controls. The patients were evaluated using visual analogue scale (VAS) at rest and the Western Ontario and McMaster Universities Arthritis Index (WOMAC). Color Doppler imaging was used to measure mid-diastolic velocity (MD), pulsatility index (PI), peak systolic velocity (PS), end-diastolic velocity (ED), vascular diameter, and flow volume in the external iliac (EIA), common femoral (CFA), superficial femoral (SFA), deep femoral (DFA), popliteal (PA), anterior tibial (ATA), posterior tibial (PTA), and distal superficial femoral arteries (DSFA). The femoral artery intima-media thickness (FIMT) was also measured. OA patients' PS and flow volume in the EIA and SFA were greater than those of controls, as were PI and ED in the EIA, ED in the PA, MD in the DFA, and the diameter of the PA, ATA, and PTA (p < 0.05). There were no statistically significant differences in FIMT between patients with knee OA and controls (p > 0.05). The flow volume of the main arteries feeding the knee joint is significantly greater than normal in patients with symptomatic knee OA. No evidence was identified relating this difference to ischemic processes.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10067-013-2440-yDOI Listing

Publication Analysis

Top Keywords

flow volume
12
lower extremity
8
blood flow
8
patients osteoarthritis
8
color doppler
8
superficial femoral
8
flow
5
femoral
5
assessment lower
4
extremity arterial
4

Similar Publications

Background: The challenges associated with traditional drug screening, such as high costs and long screening times, have led to an increase in the use of single-cell isolation technologies. Small sample volumes are required for high-throughput, cell-based assays to reduce assay costs and enable rapid sample processing. Using microfluidic chips, single-cell analysis can be conducted more effectively, requiring fewer reagents and maintaining biocompatibility.

View Article and Find Full Text PDF

Introduction: Exposure to environmental factors ( air pollution and second-hand tobacco smoke) have been associated with impaired lung function. However, the impact of environmental factors on lung health is usually evaluated separately and not with an exposomic framework. In this regard, breath analysis could be a noninvasive tool for biomonitoring of global human environmental exposure.

View Article and Find Full Text PDF

Association between impaired diffusion capacity and small airway dysfunction: a cross-sectional study.

ERJ Open Res

January 2025

State Key Laboratory of Respiratory Disease & National Clinical Research Center for Respiratory Disease & Guangzhou Institute of Respiratory Health & National Center for Respiratory Medicine & Department of Pulmonary and Critical Care Medicine, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, Guangzhou, Guangdong, China.

Background: Small airway dysfunction (SAD) and impaired diffusion capacity of the lungs for carbon monoxide ( ) are positively associated with a worse prognosis. Individuals with both dysfunctions have been identified in clinical practice and it is unknown whether they have worse health status or need management. We conducted this study to explore the association between SAD and impaired , and the difference between the groups with two dysfunctions, with either one dysfunction and with no dysfunction.

View Article and Find Full Text PDF

Tight sandstone gas reservoirs are characterized by high water saturation, significant seepage resistance, low single-well productivity, rapid decline, and low gas recovery. Enhancing the recovery rate of tight sandstone gas reservoirs is a complex engineering challenge that necessitates thorough, refined, and systematic research into its fundamental theories. This study employs a comprehensive approach integrating mercury injection, nuclear magnetic resonance, micro-model visualization, and simulation experiments of displacement and inter-layer seepage flow, alongside foundational seepage theories, to systematically explore the characteristics of tight sandstone gas reservoirs, seepage patterns, and methods for improving gas recovery.

View Article and Find Full Text PDF

In this research, the impact of differing densities and viscosities of two dissolving fluids on their mixing efficiency, as well as the effects of various excitation frequencies on the performance of the mixer, have been examined. For this purpose, a two-dimensional microchannel equipped with an oscillating circular cylinder was used, operating within a Strouhal number range of 0.1-0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!