Background/aim: The purpose of this investigation was to conduct a pilot study to evaluate the use of 3D image correlation photogrammetry (3DIC) in comparing strain characteristics of three commercially available mouthguard materials in the actual form of a mouthguard.

Material And Methods: 3DIC was used to measure strain and deformation on the surface of a mouthguard and a resin model. A computed tomographic scan of a maxilla of a patient was used to fabricate a resin test model. Three mouthguard materials were tested: conventional ethylene vinyl acetate; Proform TM, a thermoplastic material; and Polyshok TM, an EVA product containing polyurethane. Three mouthguards of each of the three materials were fabricated and fitted to the acrylic model for testing. A speckle pattern was applied to the external surfaces of each of the mouthguards. Static mechanical tests using a servohydraulic load frame at 10, 25, and 50 pounds of force were applied to the mouthguards while on the resin model. Strains were measured in both the horizontal (x) and vertical (y) axes using (3DIC). Measured strains were analysed by 4-way anova.

Results: For all three materials tested, the difference in strain between two measured directions (X and Y) was found to be statistically significant for all regions evaluated. The analysis indicated that each direction, region, and load was involved in a statistically significant effect (P < 0.001). Statistical differences in the strain were noted with the highest strain region being closest to the applied load for all three materials. Differences in strains in two directions were found to be significant for the materials studied (P < 0.001).

Conclusions: 3DIC is useful in evaluation of mouthguard materials in the actual form of a mouthguard. Materials, along with larger sample sizes, may improve confidence levels of the results. Further testing is indicated before clinical claims can be made.

Download full-text PDF

Source
http://dx.doi.org/10.1111/edt.12076DOI Listing

Publication Analysis

Top Keywords

mouthguard materials
20
three materials
12
materials
9
pilot study
8
image correlation
8
correlation photogrammetry
8
strain deformation
8
materials actual
8
actual form
8
resin model
8

Similar Publications

Background/aim: Sports mouthguard should be designed and fabricated adequately. The purpose was to propose a criterion for fabricating sports laminate mouthguard with adequate thickness for protect orofacial structures.

Materials And Methods: Ethylene vinyl acetate sheet (Sports Mouthguard) was fabricated using a pressure former.

View Article and Find Full Text PDF

The purpose of this study was to investigate the effects of acetyl tributyl citrate (ATBC) on the mechanical properties, abrasion resistance, and cytotoxicity of a polyurethane-based 3D printing resin for mouthguard applications. The synthesized polycarbonate-based polyurethane acrylate was formulated into digital light processing printing resins with 40 wt% triethylene glycol dimethacrylate, and different percentage of ATBC were added for further characterizations. The mechanical properties and abrasion resistance, ATBC migration, and the cytotoxicity of the resins were evaluated.

View Article and Find Full Text PDF

Sports-related traumatic dental injuries (TDIs) are a significant global concern, particularly in contact sports, where the risk of orofacial injuries is high. Custom-made sports mouthguards (CSMs) are recognized as the most effective means of preventing these injuries, providing both protection and comfort without impairing athletic performance. Despite their proven benefits, there is no globally standardized approach to mouthguard design, fabrication, or usage, primarily due to varying regulations, awareness levels, and cultural attitudes toward sports safety across different countries.

View Article and Find Full Text PDF

Background: Traumatic dental injuries with tracheal intubation during general anesthesia are considered one of the most common complications. It is also the primary reason for malpractice legal claims against anesthesiologists according to insurance companies. There is much information regarding the incidence, consequences, and risk factors of traumatic dental injuries during general anesthesia.

View Article and Find Full Text PDF

A mouthguard electrochemical sensor for salivary glucose detection based on platinum metal hydrogel is proposed in this work. Conventional enzyme-based electrochemical glucose sensors are fraught with issues such as high cost, oxygen dependency, intricate immobilization procedures, and susceptibility to variations in temperature, pH, and so on. The detection of glucose in saliva, as a non-invasive sensing approach, presents a more convenient solution for diabetes monitoring.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!