We describe a compact, non-contact design for a total emission detection (c-TED) system for intra-vital multiphoton imaging. To conform to a standard upright two-photon microscope design, this system uses a parabolic mirror surrounding a standard microscope objective in concert with an optical path that does not interfere with normal microscope operation. The non-contact design of this device allows for maximal light collection without disrupting the physiology of the specimen being examined. Tests were conducted on exposed tissues in live animals to examine the emission collection enhancement of the c-TED device compared to heavily optimized objective-based emission collection. The best light collection enhancement was seen from murine fat (5×-2× gains as a function of depth), whereas murine skeletal muscle and rat kidney showed gains of over two and just under twofold near the surface, respectively. Gains decreased with imaging depth (particularly in the kidney). Zebrafish imaging on a reflective substrate showed close to a twofold gain throughout the entire volume of an intact embryo (approximately 150 μm deep). Direct measurement of bleaching rates confirmed that the lower laser powers, enabled by greater light collection efficiency, yielded reduced photobleaching in vivo. The potential benefits of increased light collection in terms of speed of imaging and reduced photo-damage, as well as the applicability of this device to other multiphoton imaging methods is discussed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4132828PMC
http://dx.doi.org/10.1111/jmi.12099DOI Listing

Publication Analysis

Top Keywords

light collection
16
compact non-contact
8
total emission
8
emission detection
8
non-contact design
8
multiphoton imaging
8
emission collection
8
collection enhancement
8
collection
6
imaging
5

Similar Publications

This study investigates the electronic properties and photovoltaic (PV) performance of newly designed bithiophene-based dyes, focusing on their light harvesting efficiency (LHE), open-circuit voltage (V), fill factor (FF), and short-circuit current density (J).These new dyes are designed with the help of machine learning (ML) to design best donor acceptor designs. For this, we collect 2567 differenr electron donor groups and calculated their bandgap with the help of Random Forest (RF) Regression method.

View Article and Find Full Text PDF

The wheelchair service delivery process (SDP) is a large complex system and therefore has many potential points of failure; determining priorities for improvement is challenging. The complexities introduce several barriers to accessing and maintaining wheelchairs for individuals with mobility impairments. Given the breadth and depth of the barriers, it is important to know in which areas to focus future policy reform efforts.

View Article and Find Full Text PDF

Background: Postpartum is a critical period to interrupt weight gain across the lifespan, decrease weight-related risk in future pregnancies, promote healthy behaviors that are often adopted during pregnancy, and improve long-term health. Because the postpartum period is marked by unique challenges to a person's ability to prioritize healthy behaviors, a multi-level/domain approach to intervention beyond the individual-level factors of diet and activity is needed.

Objectives: The purpose of this study was to understand postpartum people's perceptions about the relationship between their social networks and support, and their health behaviors and weight.

View Article and Find Full Text PDF

Childhood nutrition plays an important role in the promotion of long-term health. Introducing solid foods in alignment with the Mediterranean Diet during weaning fosters a preference for healthy foods early in life. However, access to nutritious diets remains a challenge in underserved communities.

View Article and Find Full Text PDF

To establish a machine learning (ML) model for predicting prostate biopsy outcomes using prostate-specific antigen (PSA) values, multiparametric magnetic resonance imaging (mpMRI) findings, and hematologic parameters. The medical records of the patients who had undergone a prostate biopsy were evaluated. Laboratory findings, mpMRI findings, and prostate biopsy results were collected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!