A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Effects of Enhanced External Counterpulsation on Cardiac Electrophysiologic Properties of Patients with Ischemic Heart Disease and Refractory Angina at Function Class II-III. | LitMetric

Introduction: Enhanced external counterpulsation (EECP) is a noninvasive circulatory assist device that has been recently emerged as a treatment option for refractory angina or left ventricular (LV) dysfunction. The aims of this study were to examine the effects of EECP on the elecrocardiographic parameters and the heart rate variability indices of patients with the coronary heart disease and function class II-III angina resistant to medication.

Methods: In a descriptive study, the patients who presented with sever angina at function class II-III were studied. Those meeting the inclusion criteria were invited to participate and provided informed consent. The standard enhanced external counterpulsation treatment (35 one-hour procedures 5-6 times a week) was done. Thirty minute ambulatory electrocardiographic monitoring and electrocardiogram before starting and at the end of treatment sessions were done. Data entry and analysis of data was done finally.

Results: Twenty five patients with mean age 68±9 year including 21(84%) men and 4(16%) women were enrolled in this study. Electocardiogarphic parameters before and after treatment by EECP were not different statistically. Time domain indices of heart rate variability according to ambulatory monitoring findings were not changed significantly.

Conclusion: Results of this study revealed that EECP did not improve the electrocardiographic and heart rate variability parameters of ischemic heart disease patients with refractory angina at function class II or III.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3825325PMC
http://dx.doi.org/10.5681/jcvtr.2011.010DOI Listing

Publication Analysis

Top Keywords

function class
16
enhanced external
12
external counterpulsation
12
heart disease
12
refractory angina
12
angina function
12
class ii-iii
12
heart rate
12
rate variability
12
ischemic heart
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!