A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Anesthesia information management system-based near real-time decision support to manage intraoperative hypotension and hypertension. | LitMetric

Anesthesia information management system-based near real-time decision support to manage intraoperative hypotension and hypertension.

Anesth Analg

From the *Department of Anesthesiology and Pain Medicine, University of Washington; †Department of Anesthesiology, VA Puget Sound Health Care System, Seattle, Washington; and ‡Department of Applied Mathematics, National Dong Hwa University, Hualien, Taiwan.

Published: January 2014

Background: Intraoperative hypotension and hypertension are associated with adverse clinical outcomes and morbidity. Clinical decision support mediated through an anesthesia information management system (AIMS) has been shown to improve quality of care. We hypothesized that an AIMS-based clinical decision support system could be used to improve management of intraoperative hypotension and hypertension.

Methods: A near real-time AIMS-based decision support module, Smart Anesthesia Manager (SAM), was used to detect selected scenarios contributing to hypotension and hypertension. Specifically, hypotension (systolic blood pressure <80 mm Hg) with a concurrent high concentration (>1.25 minimum alveolar concentration [MAC]) of inhaled drug and hypertension (systolic blood pressure >160 mm Hg) with concurrent phenylephrine infusion were detected, and anesthesia providers were notified via "pop-up" computer screen messages. AIMS data were retrospectively analyzed to evaluate the effect of SAM notification messages on hypotensive and hypertensive episodes.

Results: For anesthetic cases 12 months before (N = 16913) and after (N = 17132) institution of SAM messages, the median duration of hypotensive episodes with concurrent high MAC decreased with notifications (Mann Whitney rank sum test, P = 0.031). However, the reduction in the median duration of hypertensive episodes with concurrent phenylephrine infusion was not significant (P = 0.47). The frequency of prolonged episodes that lasted >6 minutes (sampling period of SAM), represented in terms of the number of cases with episodes per 100 surgical cases (or percentage occurrence), declined with notifications for both hypotension with >1.25 MAC inhaled drug episodes (δ = -0.26% [confidence interval, -0.38% to -0.11%], P < 0.001) and hypertension with phenylephrine infusion episodes (δ = -0.92% [confidence interval, -1.79% to -0.04%], P = 0.035). For hypotensive events, the anesthesia providers reduced the inhaled drug concentrations to <1.25 MAC 81% of the time with notifications compared with 59% without notifications (P = 0.003). For hypertensive episodes, although the anesthesia providers' reduction or discontinuation of the phenylephrine infusion increased from 22% to 37% (P = 0.030) with notification messages, the overall response was less consistent than the response to hypotensive episodes.

Conclusions: With automatic acquisition of arterial blood pressure and inhaled drug concentration variables in an AIMS, near real-time notification was effective in reducing the duration and frequency of hypotension with concurrent >1.25 MAC inhaled drug episodes. However, since phenylephrine infusion is manually documented in an AIMS, the impact of notification messages was less pronounced in reducing episodes of hypertension with concurrent phenylephrine infusion. Automated data capture and a higher frequency of data acquisition in an AIMS can improve the effectiveness of an intraoperative clinical decision support system.

Download full-text PDF

Source
http://dx.doi.org/10.1213/ANE.0000000000000027DOI Listing

Publication Analysis

Top Keywords

decision support
16
intraoperative hypotension
12
hypotension hypertension
12
inhaled drug
12
phenylephrine infusion
12
anesthesia management
8
clinical decision
8
systolic blood
8
blood pressure
8
concurrent phenylephrine
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!