Purpose: Arterial spin labeling (ASL) perfusion imaging with a segmented three-dimensional (3D) readout is becoming increasing popular, yet conventional motion correction approaches cannot be applied in segmented imaging. The purpose of this study was to demonstrate the integration of 3D pseudocontinuous ASL (PCASL) and PROMO (PROspective MOtion correction) for cerebral blood flow measurements.
Methods: PROMO was integrated into 3D PCASL without increasing repetition time. PCASL was performed with and without PROMO in the absence of motion. The performance of PCASL-PROMO was then evaluated with controlled motions using separate scans with and without PROMO and also with random motion using an interleaved scan where every repetition time is repeated twice, once with and once without PROMO.
Results: The difference in the average ASL signal of the 3D volume between conventional and PROMO implementations was negligible (<0.2%). ASL image artifacts from both controlled and random motions were removed significantly with PROMO, showing improved correlation with reference images. Multiple combinations of data acquired using the interleaved scan revealed that PROMO with real-time motion updating alone reduces motion artifact significantly and that rescanning of corrupted segments is more critical in tagged images than control images.
Conclusion: This study demonstrates that PROMO is a successful approach to motion correction for PCASL cerebral blood flow imaging.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4048655 | PMC |
http://dx.doi.org/10.1002/mrm.25024 | DOI Listing |
J Comput Chem
January 2025
Scuola Superiore Meridionale, Napoli, Italy.
Light-driven molecular rotary motors are nanometric machines able to convert light into unidirectional motions. Several types of molecular motors have been developed to better respond to light stimuli, opening new avenues for developing smart materials ranging from nanomedicine to robotics. They have great importance in the scientific research across various disciplines, but a detailed comprehension of the underlying ultrafast photophysics immediately after photo-excitation, that is, Franck-Condon region characterization, is not fully achieved yet.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Electrical and Electronic Engineering, Yonsei University, Seoul 03722, Republic of Korea.
Video frame interpolation (VFI) is a task that generates intermediate frames from two consecutive frames. Previous studies have employed two main approaches to extract the necessary information from both frames: pixel-level synthesis and flow-based methods. However, when synthesizing high-resolution videos using VFI, each approach has its limitations.
View Article and Find Full Text PDFJ Mol Model
January 2025
INIFTA, DQT, Sucursal 4, C. C. 16, 1900, La Plata, Argentina.
Quantum mechanics has proved to be suitable for the study of molecular systems. In particular, the Born-Oppenheimer approximation enables one to separate the motions of electrons and nuclei. In the case of diatomic molecules, this approximation leads to the so-called potential-energy function that provides the interaction between the two nuclei.
View Article and Find Full Text PDFPurpose: With the widespread introduction of dual energy computed tomography (DECT), applications utilizing the spectral information to perform material decomposition became available. Among these, a popular application is to decompose contrast-enhanced CT images into virtual non-contrast (VNC) or virtual non-iodine images and into iodine maps. In 2021, photon-counting CT (PCCT) was introduced, which is another spectral CT modality.
View Article and Find Full Text PDFBiol Res Nurs
January 2025
Cognitive Neuroscience, Pain and Rehabilitation Research Group (NECODOR), Faculty of Health Sciences, Rey Juan Carlos University, Alcorcón, Spain.
This cross-sectional study compared plasma brain-derived neurotrophic factor (BDNF) levels among chronic primary musculoskeletal pain patients, chronic widespread pain patients, and asymptomatic controls. The study included 126 participants aged 18-65, divided into three groups of 42 each. Pain intensity was assessed using a Numeric Rating Scale (NRS), and plasma BDNF levels were measured via ELISA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!