4D image-guided radiation therapy (IGRT) for free-breathing lungs is challenging due to the complicated respiratory dynamics. Effective modeling of respiratory motion is crucial to account for the motion affects on the dose to tumors. We propose a shape-correlated statistical model on dense image deformations for patient-specic respiratory motion estimation in 4D lung IGRT. Using the shape deformations of the high-contrast lungs as the surrogate, the statistical model trained from the planning CTs can be used to predict the image deformation during delivery verication time, with the assumption that the respiratory motion at both times are similar for the same patient. Dense image deformation fields obtained by diffeomorphic image registrations characterize the respiratory motion within one breathing cycle. A point-based particle optimization algorithm is used to obtain the shape models of lungs with group-wise surface correspondences. Canonical correlation analysis (CCA) is adopted in training to maximize the linear correlation between the shape variations of the lungs and the corresponding dense image deformations. Both intra- and inter-session CT studies are carried out on a small group of lung cancer patients and evaluated in terms of the tumor location accuracies. The results suggest potential applications using the proposed method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3824262PMC
http://dx.doi.org/10.1117/12.843974DOI Listing

Publication Analysis

Top Keywords

respiratory motion
20
dense image
12
statistical model
8
image deformations
8
image deformation
8
respiratory
6
motion
6
image
5
shape-correlated deformation
4
deformation statistics
4

Similar Publications

Cine-magnetic resonance imaging (MRI) has been used to track respiratory-induced motion of the liver and tumor and assist in the accurate delineation of tumor volume. Recent developments in compressed sensitivity encoding (SENSE; CS) have accelerated temporal resolution while maintaining contrast resolution. This study aimed to develop and assess hepatobiliary phase (HBP) cine-MRI scans using CS.

View Article and Find Full Text PDF

Objectives: Implementation of diffusion-weighted imaging (DWI) for abdominal imaging in children has challenges due to motion artifacts exacerbated by long acquisition times. We aimed to compare acquisition time and image quality between conventional DWI and multi-band (MB) DWI of the liver in children and young adults.

Methods: Clinical MRI exams from May 2023 to January 2024 were reviewed, including four DWI sequences: respiratory-triggered (RTr, clinical standard), free-breathing (FB), MB-DWI with shift factor 1 (MBsf1), and MB-DWI with shift factor 2 (MBsf2).

View Article and Find Full Text PDF

Purpose: To evaluate the image quality of an ultrafast cone-beam computed tomography (CBCT) system-Varian HyperSight.

Methods And Materials: In this evaluation, 5 studies were performed to assess the image quality of HyperSight CBCT. First, a HyperSight CBCT image quality evaluation was performed and compared with Siemens simulation-CT and Varian TrueBeam CBCT.

View Article and Find Full Text PDF

Background: Respiratory motion is a challenge for accurate radiotherapy that may be mitigated by real-time tracking. Commercial tracking systems utilize a hybrid external-internal correlation model (ECM), integrating continuous external breathing monitoring with sparse X-ray imaging of the internal tumor position.

Purpose: This study investigates the feasibility of using the next generation reservoir computing (NG-RC) model as a hybrid ECM to transform measured external motions into estimated 3D internal motions.

View Article and Find Full Text PDF

Purpose: The goal of this study was to assess the feasibility of a cost-effective prototype of a laser-based respiratory motion detection system utilizing a Leuze LDS for breath monitoring through calibration and volunteer tests.

Methods: This study was performed using the Anzai AZ-773 V and computerized imaging reference systems (CIRS) motion phantoms for calibration tests. The calibration of the laser-based respiratory motion detection system involved spatial accuracy testing, amplitude calibration, and temporal accuracy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!