Plastic optical fibre sensor for spine bending monitoring with power fluctuation compensation.

Sensors (Basel)

Department of Electronic and Computer Engineering, University of Limerick, Plassey Rd., Limerick, Ireland.

Published: October 2013

This paper presents the implementation of power fluctuation compensation for an intensity-based optical fibre bending sensor aimed at monitoring human spine bending in a clinical environment. To compensate for the light intensity changes from the sensor light source, a reference signal was provided via the light reflection from an aluminum foil surface fixed at a certain distance from the source fibre end tips. From the results, it was found that the investigated sensor compensation technique was capable of achieving a 2° resolution for a bending angle working range between 0° and 20°. The study also suggested that the output voltage ratio has a 0.55% diversion due to input voltage variation between 2.9 V and 3.4 V and a 0.25% output drift for a 2 h measurement. With the achieved sensor properties, human spine monitoring in a clinical environment can potentially be implemented using this approach with power fluctuation compensation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3871115PMC
http://dx.doi.org/10.3390/s131114466DOI Listing

Publication Analysis

Top Keywords

power fluctuation
12
fluctuation compensation
12
optical fibre
8
spine bending
8
human spine
8
clinical environment
8
sensor
5
plastic optical
4
fibre sensor
4
sensor spine
4

Similar Publications

Variable power functional dilution adjustment of spot urine.

Sci Rep

January 2025

Praxis Dr.Carmine, Etzelstrasse 21, Pfaeffikon SZ, 8808, Switzerland.

Spot-urinary biomarkers are crucial in medical, epidemiological, and environmental studies, but their variability due to hydration levels requires precise dilution adjustments. Traditional methods, like conventional creatinine correction (CCRC), are limited in compensating for variations in urine concentration, causing substantial inconsistencies, particularly at the extremes of the diuresis spectrum. While restricting the creatinine (CRN) range to 0.

View Article and Find Full Text PDF

Power spectral analysis of voltage-gated channels in neurons.

Front Neuroinform

January 2025

Centre Borelli, Université Paris Cité, UMR 9010, CNRS, Paris, France.

This article develops a fundamental insight into the behavior of neuronal membranes, focusing on their responses to stimuli measured with power spectra in the frequency domain. It explores the use of linear and nonlinear (quadratic sinusoidal analysis) approaches to characterize neuronal function. It further delves into the random theory of internal noise of biological neurons and the use of stochastic Markov models to investigate these fluctuations.

View Article and Find Full Text PDF

We consider many-particle diffusion in one spatial dimension modeled as "random walks in a random environment." A shared short-range space-time random environment determines the jump distributions that drive the motion of the particles. We determine universal power laws for the environment's contribution to the variance of the extreme first passage time and extreme location.

View Article and Find Full Text PDF

We demonstrate a wide-tunable random fiber laser (RFL) with narrow linewidth and low noise. The tunable RFL is achieved by combining random feedback from a disordered fiber Bragg grating array (FBGA) with a broad scattering wavelength range and the gain from an erbium-doped fiber (EDF) with a broad amplification wavelength range. The disordered FBGA is fabricated using a femtosecond laser direct writing technique by varying the random distances and grating periods.

View Article and Find Full Text PDF

Machine learning reveals the dynamic importance of accessory sequences for outbreak clustering.

mBio

January 2025

Department of Molecular Biology and Biochemistry, Simon Fraser University, Burnaby, British Columbia, Canada.

Unlabelled: Bacterial typing at whole-genome scales is now feasible owing to decreasing costs in high-throughput sequencing and the recent advances in computation. The unprecedented resolution of whole-genome typing is achieved by genotyping the variable segments of bacterial genomes that can fluctuate significantly in gene content. However, due to the transient and hypervariable nature of many accessory elements, the value of the added resolution in outbreak investigations remains disputed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!