  • Diffusion weighted magnetic resonance imaging (DWI) typically uses single-shot echo-planar imaging (ss EPI), which helps minimize motion artifacts but limits resolution, especially in abdominal imaging.
  • A new technique called reduced Field of View ss EPI (rFOV ss EPI) has shown to produce higher resolution images in carotid arteries and spinal cords but hasn't been applied to pancreas imaging until now.
  • In a study comparing full FOV and rFOV DWI for pancreatic tumors and normal tissues, rFOV DWI demonstrated significantly better image quality and improved spatial resolution (from 3.0mm/pixel to 1.25mm/pixel) without substantial differences in ADC values.

Article Abstract

Diffusion weighted magnetic resonance imaging (DWI) has been mostly acquired using single-shot echo-planar imaging (ss EPI) to minimize motion induced artifacts. The spatial resolution, however, is inherently limited in ss EPI especially for abdominal imaging, even with the advances in parallel imaging. A novel method of reduced Field of View ss EPI (rFOV ss EPI) has achieved high resolution DWI in human carotid artery, spinal cord with reduced blurring and higher spatial resolution than conventional ss EPI, but it has not been used to pancreas imaging. In the work, comparisons between the full FOV ss-DW EPI and rFOV ss-DW EPI in image qualities and ADC values of pancreatic tumors and normal pancreatic tissues were performed to demonstrate the feasibility of pancreatic high resolution rFOV DWI. There were no significant differences in the mean ADC values between full FOV DWI and rFOV DWI for the 17 subjects using b=600s/mm(2) (P=0.962). However, subjective scores of image quality was significantly higher at rFOV ss DWI (P=0.008 and 0.000 for b-value=0s/mm(2) and 600s/mm(2) respectively). The spatial resolution of DWI for pancreas was increased by a factor of over 2.0 (from almost 3.0mm/pixel to 1.25mm/pixel) using rFOV ss EPI technique. Reduced FOV ss EPI can provide good DW images and is promising to benefit applications for pancreatic diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2013.10.005DOI Listing

Publication Analysis

Top Keywords

high resolution
12
spatial resolution
12
rfov dwi
12
epi
9
diffusion weighted
8
weighted magnetic
8
magnetic resonance
8
resonance imaging
8
reduced field
8
field view
8

Similar Publications

A chemical investigation of Streptomyces sp. GZWMJZ-662, an endophytic actinomycete isolated from Houttuynia cordata Thunb., has yielded eleven bohemamine dimers (1-11).

View Article and Find Full Text PDF

Artificial intelligence and stroke imaging.

Curr Opin Neurol

February 2025

High Dimensional Neurology Group, UCL Queen Square Institute of Neurology, University College London, Russell Square House, Bloomsbury, London, UK.

Purpose Of Review: Though simple in its fundamental mechanism - a critical disruption of local blood supply - stroke is complicated by the intricate nature of the neural substrate, the neurovascular architecture, and their complex interactions in generating its clinical manifestations. This complexity is adequately described by high-resolution imaging with sensitivity not only to parenchymal macrostructure but also microstructure and functional tissue properties, in conjunction with detailed characterization of vascular topology and dynamics. Such descriptive richness mandates models of commensurate complexity only artificial intelligence could plausibly deliver, if we are to achieve the goal of individually precise, personalized care.

View Article and Find Full Text PDF

Herein, we report the isolation of pyridine moiety-functionalized SiNSi pincer-based bis-silylene ligand () and its reactivity toward various halide precursors (X = Br and I) of group 13 elements (M = Al, Ga, and In). This gave us straightforward access to the SiNSi pincer-coordinated group 13 cations (-). These complexes are duly characterized by single-crystal X-ray diffraction studies, multinuclear magnetic resonance spectroscopy (H, C, and Si), and high-resolution mass spectrometry techniques.

View Article and Find Full Text PDF

Reconstruction after the excision of a lower eyelid tumor should be focused on the restoration of both functionality and aesthetic appeal. Accurate identification and appropriate intervention are crucial for the favorable resolution of the condition. This technique used a nasolabial mucosal-myocutaneous propeller flap to reconstruct a huge full-thickness defection of right lower eyelid because of basal cell carcinoma.

View Article and Find Full Text PDF

Evaluating the practical utility of endangered plant species is crucial for their conservation. Nevertheless, numerous endangered plants, including Sinocalycanthus chinensis, lack historical usage data, leading to a paucity of guidance in traditional pharmacological research. This gap impedes their development and potential utilization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!