AI Article Synopsis

  • The study explores a new occipitocervical fixation method using an anterior anatomical locking plate system, which had not been previously reported.
  • A three-dimensional finite element model was created to analyze the biomechanics of this system in a stable and unstable cervical scenario, focusing on stress and strain outcomes.
  • Results showed that the locking plate system demonstrated significantly reduced displacement and stress compared to traditional screw fixation methods under various directional loads, indicating its potential clinical benefits.

Article Abstract

Background Context: Although there are many techniques for occipitocervical fixation, there have been no reports regarding occipitocervical fixation via the use of an anterior anatomical locking plate system.

Purpose: The biomechanics of this new system were analyzed by a three-dimensional finite element to provide a theoretical basis for clinical application.

Study Design: This was a modeling study.

Patient Sample: We studied a 27-year-old healthy male volunteer in whom cervical disease was excluded via X-ray examination.

Outcome Measures: The states of stress and strain of these two internal fixation devices were analyzed.

Methods: A three-dimensional finite element model of normal occiput-C2 was established based on the anatomical data from a Chinese population. An unstable model of occipital-cervical region was established by subtracting several unit structures from the normal model. An anterior occiput-to-axis locking titanium plate system was then applied and an anterior occiput-to-axis screw fixation was performed on the unstable model. Limitation of motion was performed on the surface of the fixed model, and physiological loads were imposed on the surface of the skull base.

Results: Under various loads from different directions, the peak values of displacement of the anterior occiput-to-axis locking titanium plate system decreased 15.5%, 12.5%, 14.4%, and 23.7%, respectively, under the loads of flexion, extension, lateral bending, and axial rotation. Compared with the anterior occiput-to-axis screw fixation, the peak values of stress of the anterior occiput-to-axis locking titanium plate system also decreased 3.9%, 2.9%, 9.7%, and 7.2%, respectively, under the loads of flexion, extension, lateral bending, and axial rotation.

Conclusion: The anterior occiput-to-axis locking titanium plate system proved superior to the anterior occiput-to-axis screw system both in the stress distribution and fixation stability based on finite element analysis. It provides a new clinical option for anterior occipitocervical fixation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.spinee.2013.08.025DOI Listing

Publication Analysis

Top Keywords

anterior occiput-to-axis
32
occiput-to-axis locking
20
plate system
20
finite element
16
occipitocervical fixation
16
locking titanium
16
titanium plate
16
three-dimensional finite
12
occiput-to-axis screw
12
anterior
10

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!