A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Heart rate variability as a predictor of hypotension after spinal anesthesia in hypertensive patients. | LitMetric

Heart rate variability as a predictor of hypotension after spinal anesthesia in hypertensive patients.

Korean J Anesthesiol

Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea.

Published: October 2013

Background: Hypotension is a common phenomenon after spinal anesthesia in hypertensive patients. We investigated whether heart rate variability could predict the occurrence of hypotension after spinal anesthesia in hypertensive patients.

Methods: Forty-one patients undergoing spinal anesthesia were included. Heart rate variability was measured at five different time points such as before fluid loading (baseline), after fluid loading as well as 5 min, 15 min and 30 min after spinal anesthesia. Fluid loading was performed using 5 ml/kg of a crystalloid solution. Baseline total power and low to high frequency ratio (LF/HF) in predicting hypotension after spinal anesthesia were analyzed by calculating the area under the receiver operating characteristic curves (AUC).

Results: Moderate hypotension, defined as a decrease of mean arterial pressure to below 20-30% of the baseline, occurred in 13 patients and severe hypotension, defined as a decrease of mean arterial pressure greater than 30% below the baseline, occurred in 7 patients. LF/HF ratiosand total powers did not significantly change after spinal anesthesia. AUCs of LF/HF ratio for predicting moderate hypotension was 0.685 (P = 0.074), severe hypotension was 0.579 (P = 0.560) and moderate or severe hypotension was 0.652 (P = 0.101), respectively. AUCs of total power for predicting moderate hypotension was 0.571 (P = 0.490), severe hypotension was 0.672 (P = 0.351) and moderate or severe hypotension was 0.509 (P = 0.924), respectively.

Conclusions: Heart rate variability is not a reliable predictor of hypotension after spinal block in hypertensive patients whose sympathetic activity is already depressed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3822023PMC
http://dx.doi.org/10.4097/kjae.2013.65.4.317DOI Listing

Publication Analysis

Top Keywords

spinal anesthesia
28
severe hypotension
20
heart rate
16
rate variability
16
hypotension spinal
16
hypotension
13
anesthesia hypertensive
12
hypertensive patients
12
fluid loading
12
moderate hypotension
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!