We present a novel connector that allows for easy handling and injection of sample volumes between 1 and 20 μl. All tubing connections between external pumps and the microfluidic device are established before the sample is introduced into a sealable reservoir built into the connector. This approach allows for multiple injections of small sample volumes without the need to dismantle the chip-tubing assembly. We demonstrate that the connector reservoir seal can withstand pressures of up to 6 bar, that opening or closing the reservoir does not dislocate the sample by more than 35 nl, and that the connector can be used for injecting samples into both miscible and immiscible carrier fluids.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c3lc51065dDOI Listing

Publication Analysis

Top Keywords

sample volumes
8
sample
5
chip-to-world connector
4
connector built-in
4
reservoir
4
built-in reservoir
4
reservoir simple
4
simple small-volume
4
small-volume sample
4
sample injection
4

Similar Publications

Texture analysis generates image parameters from F-18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). Although some parameters correlate with tumor biology and clinical attributes, their types and implications can be complex. To overcome this limitation, pseudotime analysis was applied to texture parameters to estimate changes in individual sample characteristics, and the prognostic significance of the estimated pseudotime of primary tumors was evaluated.

View Article and Find Full Text PDF

Salivary extracellular vesicles isolation methods impact the robustness of downstream biomarkers detection.

Sci Rep

December 2024

Sys2Diag, UMR9005 CNRS/ALCEN, Cap Gamma, Parc Euromédecine, 1682 Rue de la Valsière, CS 40182, 34184, Montpellier Cedex 4, France.

Extracellular vesicles (EVs), crucial mediators in cell-to-cell communication, are implicated in both homeostatic and pathological processes. Their detectability in easily accessible peripheral fluids like saliva positions them as promising candidates for non-invasive biomarker discovery. However, the lack of standardized methods for salivary EVs isolation greatly limits our ability to study them.

View Article and Find Full Text PDF

This micro-computed tomography (micro-CT) analysis in vitro study was designed to compare void volume in root canal fillings performed using the single-cone (SC) technique and the continuous wave condensation (CWC) technique with bioceramic (BC) sealer. Forty human-extracted, single-rooted mandibular premolars were cleaned, shaped, and divided into two groups (n = 20) based on the obturation technique. In the first group, obturation was performed using the CWC technique with TotalFill HiFlow BC sealer.

View Article and Find Full Text PDF

Background: Effective staff-to-staff and patient-provider communication in the Emergency Department (ED) is essential for safe, quality care. Routine wearing of Personal-Protective-Equipment (PPE) has introduced new challenges to communication. We aimed to understand the perspectives of ED staff about communicating while wearing PPE, and to identify factors contributing to communication success, breakdown, and repair.

View Article and Find Full Text PDF

A highly sensitive and rapid LC-MS/MS method was developed and validated for the quantification of dexamethasone in rat plasma and brain tissue. Protein precipitation method was used for sample preparation. The separation of dexamethasone and the IS (labetalol) was achieved on an Atlantis dC column using an isocratic mobile phase (10 mM ammonium formate and acetonitrile, 25/75, v/v) delivered at 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!