Photodynamic therapy to treat periimplantitis.

Implant Dent

*Department of Biomedical, Surgical and Dental Sciences, Unit of Oral Pathology and Medicine, University of Milan, Milan, Italy. †Italian Association for Metals and Biocompatibility Research-AIRMEB, Milan, Italy. ‡Private Practice, Bergamo, Italy.

Published: December 2013

Aim: : Periimplantitis is a bacterial complication after dental implants implantation. Photodynamic therapy (PDT) implies the use of low-power laser in combination with appropriate photosensitizer to increase the detoxification of the implant surfaces. Little information exists about PDT in the treatment of periimplantitis. A randomized comparative case-control study has been conducted with 20 patients and 20 controls to compare the efficacy of antimicrobial PDT versus surgical therapy in patients with periimplantitis, who have received dental implants with rough surfaces.

Materials And Methods: In the surgery group, mucoperiosteal flap surgery was used with scaling on implant surfaces and debridement of granulation tissue. Microbiologic testing was evaluated before and after intervention treatment, at 12 and 24 weeks in the study subjects.

Discussion: Total anaerobic counts of bacteria did not differ significantly between patients assigned to receive PDT and those assigned to receive surgical therapy (mean, 95.2% and 80.85%, respectively). PDT was associated with a significant decrease in bleeding scores (P = 0.02) as well as inflammatory exudation (P = 0.001).

Conclusion: Treatment with PDT in patients with periimplantitis was not associated with major reduction of total anaerobic bacteria on the rough surfaces of dental implants as compared with surgical therapy. A significantly lower proinflammatory index of periimplantitis was observed in the PDT group at 24 weeks of follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.id.0000433592.18679.91DOI Listing

Publication Analysis

Top Keywords

dental implants
12
surgical therapy
12
photodynamic therapy
8
implant surfaces
8
patients periimplantitis
8
total anaerobic
8
assigned receive
8
pdt
7
periimplantitis
6
therapy treat
4

Similar Publications

The aim of this study was to evaluate the mechanical properties and degree of conversion of a novel 3D-printing model resin and compare it to eight commercially available model resins. An experimental resin formulated by our proprietary resin technology along with DentaModel, NextDent 2, KeyModel Ultra, Rodin Model, Die and Model 2, DMR III, LCD Grey, and Grey Resin were used in this study. Parallelepiped specimens (2 × 2 × 25 mm, n = 5) were printed and measured for their flexural strength (FS), flexural modulus (FM), and modulus of resilience (MR) in accordance with ISO-4049.

View Article and Find Full Text PDF

Biosynthesis and Characterization of Silver Nanoparticles and Simvastatin Association in Titanium Biofilms.

Pharmaceuticals (Basel)

November 2024

Laboratório de Farmacologia de Antimicrobianos e Microbiologia, Faculdade de Ciências Farmacêuticas, Universidade Estadual de Campinas (UNICAMP), Campinas 13083-970, Brazil.

Introduction: Simvastatin is an antilipidemic drug that has already demonstrated antibacterial activities on oral and non-oral microorganisms. Silver nanoparticles also exhibit antimicrobial properties, particularly for coating implant surfaces. In this study, we evaluated the effects of combining simvastatin with silver nanoparticles on the formation and viability of biofilms consolidated on titanium discs.

View Article and Find Full Text PDF

Implant Surface Decontamination Methods That Can Impact Implant Wettability.

Materials (Basel)

December 2024

Department of Prosthodontics and Digital Technology, School of Dental Medicine, Stony Brook University, Stony Brook, NY 11794, USA.

This review addresses the effects of various decontamination methods on the wettability of titanium and zirconia dental implants. Despite extensive research on surface wettability, there is still a significant gap in understanding how different decontamination techniques impact the inherent wettability of these surfaces. Although the literature presents inconsistent findings on the efficacy of decontamination methods such as lasers, air-polishing, UV light, and chemical treatments, the reviewed studies suggest that decontamination alters in vitro hydrophilicity.

View Article and Find Full Text PDF

Exploring the Broad Spectrum of Titanium-Niobium Implants and Hydroxyapatite Coatings-A Review.

Materials (Basel)

December 2024

The Interdisciplinary Center for Dental Research and Development, Faculty of Dental Medicine, "Carol Davila" University of Medicine and Pharmacy, 19-21 Jean Louis Calderon Street, 020021 Bucharest, Romania.

Tooth loss replacement using dental implants is becoming more frequent. Traditional dental implant materials such as commercially pure titanium and titanium aluminum vanadium alloys have well-proven mechanical and biological properties. New titanium alloying metals such as niobium provide improved mechanical properties such as lower elastic modulus while displaying comparable or even better biocompatibility.

View Article and Find Full Text PDF

Development and Prevention of Biofilm on Cochlear Implants: A Systematic Review.

Medicina (Kaunas)

November 2024

1st Department of Pharmacology, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.

Biofilm formation on cochlear implants (CIs) poses a major problem for surgeons, leading to a high incidence of explantation and revision surgery. Therefore, developing appropriate and cost-effective biofilm detection and prevention techniques is of the essence. In this systematic review, we sought to investigate the development of biofilm formation on CIs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!