Sixteen carbamate pesticides that belong to four chemical classes (oxime-N-methylcarbamates, aryl N-methylcarbamates, N-phenylcarbamates, and methyl esters of substituted carbamic acids) were investigated via three different commercially available thermospray interfaces and ion sources that exhibit wide differences in source geometry. Comparisons were made between the three interfaces with respect to ion formation and sensitivity of detection. Experimental parameters were standardized to obtain comparable experimental conditions. Very similar mass spectra for most carbamates were obtained that illustrate independence from the geometry of the ionization and desolvation chambers of the interfaces. These findings are in sharp contrast to several literature reports. However, thermally labile carbamates gave unsatisfactory results with regard to spectral compatibility between the interfaces. Such differences were due to thermally assisted hydrolysis reactions that occur in the vaporizer probe prior to ionization and reflect differences in the vaporizer designs. The study proves conclusively that comparable spectra can be obtained under thermospray with different interfaces and mass spectrometers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/1044-0305(95)00235-6DOI Listing

Publication Analysis

Top Keywords

thermospray interfaces
12
carbamate pesticides
8
source geometry
8
interfaces
6
comparative study
4
study thermospray
4
interfaces carbamate
4
pesticides influence
4
influence ion
4
ion source
4

Similar Publications

The complex chemistry occurring at the interface between liquid and vapor phases contributes significantly to the dynamics and evolution of numerous chemical systems of interest, ranging from damage to the human lung surfactant layer to the aging of atmospheric aerosols. This work presents two methodologies to eject droplets from a liquid water surface and analyze them via mass spectrometry. In bursting bubble ionization (BBI), droplet ejection is achieved via the formation of a jet following bubble rupture at the surface of a liquid to yield 250 μm diameter droplets (10 nL volume).

View Article and Find Full Text PDF

Atmospheric pressure thermospray ionization using a heated microchip nebulizer.

Rapid Commun Mass Spectrom

October 2009

Department of Pharmaceutical Chemistry, University of Kuopio, P.O. Box 1627, FI-70211 Kuopio, Finland.

When a standard atmospheric pressure chemical ionization (APCI) or atmospheric pressure photoionization (APPI) ion source is used without applying the corona discharge or photoirradiation, atmospheric pressure thermospray ionization (APTSI) of various compounds can be achieved. Although largely ignored, this phenomenon has recently gained interest as an alternative ionization technique. In this study, this technique is performed for the first time on a miniaturized scale using a microchip nebulizer.

View Article and Find Full Text PDF

The exceptional ability of alpha-tocopherol (alpha-TOH) for scavenging free radicals is believed to also underlie its protective functions in respiratory epithelia. Phenols, however, can scavenge other reactive species. Herein, we report that alpha-TOH/alpha-TO(-) reacts with closed-shell O(3)(g) on the surface of inert solvent microdroplets in < 1 ms to produce persistent alpha-TO-O(n)(-)(n = 1-4) adducts detectable by online thermospray ionization mass spectrometry.

View Article and Find Full Text PDF

Fifty-seven years after NO(x) (NO + NO(2)) were identified as essential components of photochemical smog, atmospheric chemical models fail to correctly predict *OH/HO(2)* concentrations under NO(x)-rich conditions. This deficiency is due, in part, to the uncertain rates and mechanism for the reactive dissolution of NO(2)(g) (2NO(2) + H(2)O = NO(3)(-) + H(+) + HONO) in fog and aerosol droplets. Thus, state-of-the-art models parametrize the uptake of NO(2) by atmospheric aerosol from data obtained on "deactivated tunnel wall residue".

View Article and Find Full Text PDF

A high efficiency nebulizer (HEN) coupled to a heated spray chamber and a membrane desolvator is used for liquid sample introduction in chemical reaction interface mass spectrometry (CRIMS). Compared to the conventional thermospray nebulizer operated at solvent flow rate of 1 mL/min, the HEN provides small droplets at lower flow rates (10-100 microL/min), improving the desolvation and analyte transport efficiency. As a result, the sensitivity for carbon detection by CRIMS is improved by a factor of 4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!