High cycle fatigue behavior of implant Ti-6Al-4V in air and simulated body fluid.

Biomed Mater Eng

Department of Mechanics and Engineering Science, Sichuan University, Chengdu 610065, China.

Published: June 2014

Ti-6Al-4V implants that function as artificial joints are usually subjected to long-term cyclic loading. To study long-term fatigue behaviors of implant Ti-6Al-4V in vitro and in vivo conditions exceeding 107 cycles, constant stress amplitude fatigue experiments were carried out at ultrasonic frequency (20 kHz) with two different surface conditions (ground and polished) in ambient air and in a simulated body fluid. The initiation mechanisms of fatigue cracks were investigated with scanning electron microscopy. Improvement of fatigue strength is pronounced for polished specimens below 106 cycles in ambient air since fatigue cracks are initiated from surfaces of specimens. While the cycles exceed 106, surface conditions have no effect on fatigue behaviors because the defects located within the specimens become favorable sites for crack initiation. The endurance limit at 108 cycles of polished Ti-6Al-4V specimens decreases by 7% if it is cycled in simulated body fluid instead of ambient air. Fracture surfaces show that fatigue failure is initiated from surfaces in simulated body fluid. Surface improvement has a beneficial effect on fatigue behaviors of Ti-6Al-4V at high stress amplitudes. The fatigue properties of Ti-6Al-4V deteriorate and the mean endurance limits decrease significantly in simulated body fluid.

Download full-text PDF

Source
http://dx.doi.org/10.3233/BME-130807DOI Listing

Publication Analysis

Top Keywords

simulated body
20
body fluid
20
fatigue behaviors
12
ambient air
12
fatigue
10
implant ti-6al-4v
8
air simulated
8
surface conditions
8
fatigue cracks
8
initiated surfaces
8

Similar Publications

Analysis of the Biomechanical Effects of Vertebral Body Tethering with Apical Fusion.

Spine (Phila Pa 1976)

January 2025

Teaching and Research Area Experimental Orthopaedics and Trauma Surgery, Uniklinik RWTH Aachen, Aachen, Germany.

Study Design: Biomechanical study by using a multi-body simulation approach.

Objective: Objectification of spinal biomechanics after Vertebral Body Tethering with and without Apical Fusion.

Summary Of Background Data: Vertebral body tethering, a motion preserving surgical technique for correction of adolescent idiopathic scoliosis, is increasingly being used for thoracolumbar curves.

View Article and Find Full Text PDF

In this paper, we present a global reactive motion planning framework designed for robotic manipulators navigating in complex dynamic environments. Utilizing local minima-free circular fields, our methodology generates reactive control commands while also leveraging global environmental information from arbitrary configuration space motion planners to identify promising trajectories around obstacles. Furthermore, we extend the virtual agents framework introduced in Becker et al.

View Article and Find Full Text PDF

Background: Stereotactic body radiation therapy (SBRT) is crucial for treating early-stage inoperable non-small cell lung cancer (NSCLC) due to its precision and high-dose delivery. This study aimed to investigate the dosimetric deviations in gated (GR) versus non-gated radiotherapy (NGR), analyzing the impact of tumor location, target volume, and tumor motion range on dose distribution accuracy.

Methods: Sixty patients treated with either gated (n=30) or non-gated (n=30) SBRT for early-stage NSCLC were retrospectively analyzed.

View Article and Find Full Text PDF

All cells in the human body, including cancer cells, possess specific electrical properties crucial for their functions. These properties are notably different between normal and cancerous cells. Cancer cells are characterized by autonomous oscillations and damped electromagnetic field (EMF) activation.

View Article and Find Full Text PDF

Titanium alloys are widely used in the manufacture of orthopedic prosthesis given their excellent mechanical properties and biocompatibility. However, the primary drawbacks of traditional titanium alloy prosthesis are their much higher elastic modulus than cancellous bone and poor interfacial adhesion, which lead to poor osseointegration. 3D-printed porous titanium alloys can partly address these issues, but their bio-inertness still requires modifications to adapt to different physiological and pathological microenvironments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!