A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of short-term in vivo precision of bone density and microarchitecture at the distal radius and tibia between postmenopausal women and young adults. | LitMetric

AI Article Synopsis

  • The study aimed to compare the precision of bone property measurements using high-resolution peripheral quantitative computed tomography (HR-pQCT) between postmenopausal women and young adults.
  • The research involved scanning the distal radius and tibia of 34 postmenopausal women (average age 74) and 30 young adults (average age 27) at two different time points.
  • Results showed no significant differences in measurement precision between both groups, indicating that HR-pQCT produces similar short-term precision errors for bone outcomes in postmenopausal women and young adults.

Article Abstract

The purpose was to assess whether precision of bone properties derived via the use of high-resolution peripheral quantitative computed tomography (HR-pQCT) differs between postmenopausal women and young adults. Using HR-pQCT, we scanned the distal radius and tibia at 2 time points in 34 postmenopausal women (74 ± 7 years) and 30 young adults (mean age ± SD: 27 ± 9 years). Standard protocols were used to acquire bone area, density, and microarchitectural properties. We calculated coefficients of variation (CV; percentage CV and percentage CV of the root mean square) and 95% limits of agreement (95% LOA) to assess precision errors. The 95% LOA is the magnitude of individual change needed to be observed to ensure that a real change has occurred. Multiple Mann-Whitney U-tests (with the use of Bonferroni correction for multiple comparisons) were used to compare percentage CV between the 2 groups. Significance was set to p < 0.004. All standard outcome variables were not significantly different between the groups. The 95% LOA confirmed that the measurement bias between the groups did not differ. These results suggest that short-term precision errors in HR-pQCT-derived bone outcomes are similar between postmenopausal women and young adults.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jocd.2013.09.014DOI Listing

Publication Analysis

Top Keywords

postmenopausal women
16
young adults
16
women young
12
95% loa
12
precision bone
8
distal radius
8
radius tibia
8
assess precision
8
precision errors
8
comparison short-term
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!