A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

γ-Cyclodextrin nanoparticle eye drops with dorzolamide: effect on intraocular pressure in man. | LitMetric

Purpose: To test a new drug delivery platform with dorzolamide γ-cyclodextrin (γCD) nanoparticle eye drops for intraocular pressure (IOP) control and safety and compare with Trusopt.(®)

Methods: Self-aggregating γCD nanoparticle eye drops containing 3% dorzolamide were given once a day (QD) and compared with Trusopt given three times a day (TID) in a prospective randomized single masked crossover trial over 24 h. Seventeen subjects with IOP over 18 mmHg were recruited. IOP was measured with an Icare Tonometer Pro.(®)

Results: There was no statistically significant difference in the IOP lowering effect of dorzolamide nanoparticle eye drops QD and Trusopt TID. At peak (4 h), the IOP reduction from baseline was 3.8±2.6 mmHg (18%, P<0.05) in the nanoparticle eye drop group and 3.1±3.7 mmHg in the Trusopt group (14%, P<0.05, P=0.97 between groups). At trough (24 h), the IOP reduction was 1.4±2.8 mmHg (6%, P>0.05) in nanoparticle eye drop group and 1.5±2.0 mmHg (7%, P>0.05) in the Trusopt group (P=0.23 between groups). Burning sensation measured on the visual analogue scale (1-100) was less from the nanoparticle eye drops (12±15) than from the Trusopt (37±30), (P=0.0038). Visual acuity and conjunctival hyperemia did not differ between the two groups.

Conclusions: Dorzolamide cyclodextrin nanoparticle eye drops QD lower IOP and the effect seems comparable to Trusopt given TID. The nanoparticle eye drops are well tolerated and seem to have a better safety profile than Trusopt.

Download full-text PDF

Source
http://dx.doi.org/10.1089/jop.2013.0060DOI Listing

Publication Analysis

Top Keywords

nanoparticle eye
28
eye drops
28
drops dorzolamide
8
intraocular pressure
8
γcd nanoparticle
8
trusopt tid
8
eye
7
drops
7
nanoparticle
6
iop
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!