One thousand three-hundred and ninety-four drinking water sources comprising ground water, surface water and piped supplies were tested in order to compare the presence-absence (P-A) test with standard MPN method to detect coliforms as indicators of water quality. Out of 1394 samples, 1074 (77.04%) and 1030 (74.88%) were positive by the MPN and P-A test, respectively. The P-A test detected 96% of the positives detected by the MPN test. The P-A test may be effectively used as a rapid screening method to detect coliform contamination in less polluted sources such as ground water and piped supplies.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF00546661DOI Listing

Publication Analysis

Top Keywords

p-a test
20
presence-absence p-a
8
drinking water
8
ground water
8
water piped
8
piped supplies
8
method detect
8
test p-a
8
test
7
water
6

Similar Publications

Introduction: Intensive research is dedicated to the development of novel biomaterials and medical devices to be used as grafts in reconstructive surgery, with the purpose of enhancing their therapeutic effectiveness, safety, and durability. A variety of biomaterials, from autologous bone to polymethylmetacrylate, polyether ether ketone, titanium, and calcium-based ceramics are used in cranioplasty. Porous hydroxyapatite (PHA) is reported as a possible material for bone reconstruction, with good signs of biocompatibility, osteoconductive and osteointegrative properties.

View Article and Find Full Text PDF

Retinal Protection of New Nutraceutical Formulation.

Pharmaceutics

January 2025

Innovation and Medical Science, SIFI S.p.A., 95025 Aci Sant'Antonio, Italy.

Retinal ganglion cell (RGC) protection represents an unmet need in glaucoma. This study assessed the neuroprotective, antioxidant, and anti-inflammatory effect of a new nutraceutical formulation named Epicolin, based on citicoline, homotaurine, epigallocatechin-3-gallate, forskolin, and vitamins, through in vitro and in vivo studies. The neuroprotective effect of Epicolin or its single components, and Epicolin compared to an untreated control and two marketed formulations [Formulation G (FG) and N (FN)], was evaluated in neuroblastoma cells (SH-SY5Y) challenged with staurosporine.

View Article and Find Full Text PDF

Optimization of In-Situ Growth of Superconducting Al/InAs Hybrid Systems on GaAs for the Development of Quantum Electronic Circuits.

Materials (Basel)

January 2025

CNR-IOM-Istituto Officina dei Materiali, Consiglio Nazionale delle Ricerche, 34149 Trieste, Italy.

Hybrid systems consisting of highly transparent channels of low-dimensional semiconductors between superconducting elements allow the formation of quantum electronic circuits. Therefore, they are among the novel material platforms that could pave the way for scalable quantum computation. To this aim, InAs two-dimensional electron gases are among the ideal semiconductor systems due to their vanishing Schottky barrier; however, their exploitation is limited by the unavailability of commercial lattice-matched substrates.

View Article and Find Full Text PDF

Improving Replication in Endometrial Omics: Understanding the Influence of the Menstrual Cycle.

Int J Mol Sci

January 2025

Department of Obstetrics and Gynaecology, University of Melbourne, and Gynaecology Research Centre, Royal Women's Hospital, Parkville, VIC 3052, Australia.

The dynamic nature of human endometrial tissue presents unique challenges in analysis. Despite extensive research into endometrial disorders such as endometriosis and infertility, recent systematic reviews have highlighted concerning issues with the reproducibility of omics studies attempting to identify biomarkers. This review examines factors contributing to poor reproducibility in endometrial omics research.

View Article and Find Full Text PDF

The Erythrocyte Sedimentation Rate (ESR) in Veterinary Medicine: A Focused Review in Dogs and Cats.

Animals (Basel)

January 2025

Clinica Veterinaria Colombo, VetPartners Italia, V.le Colombo 153, 55041 Camaiore, Italy.

The erythrocyte sedimentation rate (ESR) measures the rate at which erythrocytes aggregate and sediment in a fixed time in an anticoagulated blood tube and is expressed as a speed (mm/h). The ESR is still widely used in human medicine mainly as a modified or alternate method to the original Westergren. In veterinary medicine, it was employed in the 1940s-1960s after which it was gradually abandoned or rarely employed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!