A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A ratiometric fluorescent detection of Zn(II) in aqueous solutions using pyrene-appended histidine. | LitMetric

A ratiometric fluorescent detection of Zn(II) in aqueous solutions using pyrene-appended histidine.

Bioorg Med Chem Lett

Bioorganic Chemistry Laboratory, Department of Chemistry and Chemical Engineering, Inha University, 100 Inha-ro, Nam-Gu, Incheon 402-751, Republic of Korea.

Published: December 2013

A fluorescent chemosensor, Py-His, based on histidine was easily synthesized in solid phase synthesis. Py-His displayed a highly sensitive ratiometric response to Zn(II) with potent binding affinity (Ka = 1.17 × 10(13)M(-2)) in aqueous solutions. The detection limit of Py-His for Zn(II) was calculated as 80.8 nM. Moreover, Py-His distinguished Zn(II) and Hg(II) by different ratiometric response type; the chemosensor showed a more enhanced increase of excimer emission intensity to Zn(II) than Hg(II). Upon addition of Ag(I) and Cu(II), Py-His showed a turn-off response mainly due to the quenching effect of these metal ions. The binding stoichiometry (2:1 or 1:1) of Py-His to target metal ions played a critical role in the fluorescent response type (ratiometric and turn off response) to target metal ions. The role of imidazole group of Py-His for ratiometric detection of Zn(II) was proposed by pH titration experiments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bmcl.2013.10.015DOI Listing

Publication Analysis

Top Keywords

metal ions
12
detection znii
8
aqueous solutions
8
ratiometric response
8
znii hgii
8
response type
8
target metal
8
py-his
7
znii
6
ratiometric
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!