This biomechanical study is the first to compare 3 fixation methods-bilateral fixed-angle plate, modified anterior tension wiring, and cannulated lag screws with anterior tension wiring-in multifragmentary distal patella fractures. A T-shaped 3-part fracture simulating a multifragmentary articular distal patella fracture (AO/OTA 34-C2.2) was created in 18 human cadaver knee specimens. Three groups were created using homogenous ages and bone mineral densities based on the fixation method received. Repetitive testing over 100 cycles was performed by moving the knee against gravity from 90° flexion to full extension. Failure was defined as fracture displacement greater than 2 mm. In all patellae using fixed-angle plates, an anatomical fracture reduction could be maintained throughout cyclic testing, whereas anterior tension wiring and lag screws with tension wiring showed significant fracture displacement after 100 cycles, with mean fracture gaps of 2.0±1.3 and 1.9±1.6 mm, respectively. The differences in fracture gaps between the fixed-angle plate group and the other 2 groups were statistically significant. In both groups using tension wiring, half of the constructs (3 of 6 in each group) failed due to a fracture displacement greater than 2 mm. The bilateral fixed-angle plate was the only fixation method that sustainably stabilized a multifragmentary articular distal patella fracture during cyclic loading when compared with modified anterior tension wiring and cannulated lag screws with anterior tension wiring.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3928/01477447-20131021-29 | DOI Listing |
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
January 2025
Department of Joint and Bone Surgery, the First Affiliated Hospital of Wannan Medical College, Wuhu Anhui, 241000, P. R. China.
Objective: To explore the feasibility and effectiveness of suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique for avulsion fractures of the inferior pole of the patella.
Methods: A clinical data of 38 patients with avulsion fractures of the inferior pole of the patella, who met the selective criteria and were admitted between September 2021 and April 2023, was retrospectively analyzed. The fractures were treated with suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique in 18 cases (group A) and steel wire tension-band fixation in 20 cases (group B).
Vet Comp Orthop Traumatol
January 2025
Veterinary Specialists of Sydney, Sydney, New South Wales, Australia.
Objective: To determine (1) whether the tibial plateau angle (TPA) in dogs with Salter-Harris type 1 (SH-1) or type 2 (SH-2) fractures of the proximal tibial physis significantly decreases in the time between diagnosis and reevaluation following surgical repair and (2) whether the method of surgical repair influences the change in TPA over time.
Study Design: This study was a retrospective study. Medical records from 2017 to 2022 were reviewed to identify dogs with SH-1 or SH-2 fractures of the proximal tibial physis that had undergone surgical repair with Kirschner wires (K-wires), with or without a tibial tuberosity tension band.
BMC Musculoskelet Disord
January 2025
Department of Orthopedic Surgery, The Second Hospital Affiliated to Shenyang Medical College, Shenyang City, Liaoning Province, China.
Objective: The treatment of comminuted inferior pole patellar fractures has long posed a challenge for orthopedic surgeons. This study aims to compare the biomechanical stability and clinical efficacy of Kirschner wire tension band combined with anchor cross-suture fixation versus traditional partial patellectomy in the treatment of comminuted inferior pole patellar fractures.
Methods: A retrospective analysis was conducted on 14 patients who underwent Kirschner wire tension band combined with anchor cross-suture fixation (Group A) in our department of orthopedics from September 2020 to April 2022.
Handchir Mikrochir Plast Chir
January 2025
Hand Surgery, Baltalimani Special Hospital for Bone Diseases, Istanbul, Turkey.
Purpose: This study aims to compare the clinical and radiological outcomes of three different techniques used in the surgical treatment of ulnar styloid fractures.
Material And Method: Ulnar styloid fractures treated surgically between 2012 and 2022 were evaluated retrospectively. There were three groups in the study: Group I (Kirschner wire, N= 19), Group II (tension band, N= 27) and Group III (headless compression screw, N= 25).
J Orthop Surg Res
January 2025
Guizhou Medical University, Beijing Jishuitan Hospital Guizhou Hospital, Guiyang, Guizhou, People's Republic of China.
Background: Wound repair methods are commonly used in clinical practice, such as skin graft and flap repair, which can cause secondary injuries, and high costs. Many methods for skin stretching and repair have been reported domestically and internationally. However, their clinical use is limited owing to lack of equipment, complexity, and high costs.