In this study a serial multi-cyclone sampling array capable of simultaneously sampling particles of multiple size fractions, from an occupational environment, for use in in vivo and in vitro toxicity studies and physical/chemical characterization, was developed and tested. This method is an improvement over current methods used to size-segregate occupational aerosols for characterization, due to its simplicity and its ability to collect sufficient masses of nano- and ultrafine sized particles for analysis. This method was evaluated in a chamber providing a uniform atmosphere of dust concentrations using crystalline silica particles. The multi-cyclone sampling array was used to segregate crystalline silica particles into four size fractions, from a chamber concentration of 10 mg/m(3). The size distributions of the particles collected at each stage were confirmed, in the air, before and after each cyclone stage. Once collected, the particle size distribution of each size fraction was measured using light scattering techniques to further confirm the size distributions. As a final confirmation, scanning electron microscopy was used to collect images of each size fraction. The results presented here, using multiple measurement techniques, show that this multi-cyclone system was able to successfully collect distinct size-segregated particles at sufficient masses to perform toxicological evaluations and physical/chemical characterization.

Download full-text PDF

Source
http://dx.doi.org/10.1080/15459624.2013.818244DOI Listing

Publication Analysis

Top Keywords

multi-cyclone sampling
12
sampling array
12
occupational aerosols
8
size fractions
8
physical/chemical characterization
8
sufficient masses
8
crystalline silica
8
silica particles
8
size distributions
8
size fraction
8

Similar Publications

Incineration is not a final disposal method for sludge management since a significant amount of ash is generated. Although some published literature reported on the use of sewage sludge ashes (SSAs) as a cement replacement, none of them referred to the air pollution control unit of the incinerator where the SSA is collected. The properties of SSAs from different air pollution control units were investigated with the purpose of usage as a cement replacement in the present study.

View Article and Find Full Text PDF

Aerodynamic size separation of glass fiber aerosols.

J Occup Environ Hyg

June 2020

Dust, Ventilation, and Toxic Substances Branch, Pittsburgh Mining Research Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Pittsburgh, Pennsylvania.

The objective of this study was to investigate the efficacy of an aerodynamic separation scheme for obtaining aerosols with nearly monodisperse fiber lengths as test samples for mechanistic toxicological evaluations. The approach involved the separation of aerosolized glass fibers using an Aerodynamic Aerosol Classifier (AAC) or a multi-cyclone sampling array, followed by the collection of separated samples on filter substrates, and the measurement of each sample fiber length distribution. A glass fiber aerosol with a narrow range of aerodynamic sizes was selected and sampled with the AAC or multi-cyclone sampling array in two separate setups.

View Article and Find Full Text PDF

In this study a serial multi-cyclone sampling array capable of simultaneously sampling particles of multiple size fractions, from an occupational environment, for use in in vivo and in vitro toxicity studies and physical/chemical characterization, was developed and tested. This method is an improvement over current methods used to size-segregate occupational aerosols for characterization, due to its simplicity and its ability to collect sufficient masses of nano- and ultrafine sized particles for analysis. This method was evaluated in a chamber providing a uniform atmosphere of dust concentrations using crystalline silica particles.

View Article and Find Full Text PDF

Determining the spatial variability of personal sampler inlet locations.

J Occup Environ Hyg

September 2007

NIOSH, Pittsburgh Research Laboratory, Pittsburgh, Pennsylvania 15236, USA.

This article examines the spatial variability of dust concentrations within a coal miner's breathing zone and the impact of sampling location at the cap lamp, nose, and lapel. Tests were conducted in the National Institute for Safety and Health Pittsburgh Research Laboratory full-scale, continuous miner gallery using three prototype personal dust monitors (PDM). The dust masses detected by the PDMs were used to calculate the percentage difference of dust mass between the cap lamp and the nose and between the lapel and the nose.

View Article and Find Full Text PDF