A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of respiratory system mechanics during inspiration and expiration by FLow-controlled EXpiration (FLEX): a pilot study in anesthetized pigs. | LitMetric

Background: Differences between inspiratory and expiratory lung mechanics result in the hysteresis of the pressure volume-loop. While hysteresis area is a global parameter describing the difference between inspiration and expiration in mechanics under quasi-static conditions, a detailed analysis of this difference under the dynamic conditions of mechanical ventilation is feasible once inspiratory and expiratory compliance (Cin/Cex) are determined separately. This requires uncoupling of expiratory flow rate and volume (V).

Methods: Five piglets were mechanically ventilated at positive end-expiratory pressure (PEEP) levels ranging from 0 to 15 cmH2O. Expiratory flow rate was linearized by a computer-controlled resistor (flow-controlled expiration). The volume-dependent Cin(V) and Cex(V) profiles were calculated from the tracheal pressure volume-loops.

Results: The intratidal curve-progression of Cex(V) was altogether higher with a steeper slope compared to Cin(V). With increasing positive end-expiratory pressure (PEEP) dynamic hysteresis area decreased and Cex(V) tended to run more parallel to Cin(V).

Conclusion: The relation between inspiratory and expiratory compliance profiles is associated with the hysteresis area and behaves PEEP dependent. Analysing the Cin-Cex-relation might therefore potentially offer a new approach to titrate PEEP and tidal volume.

Download full-text PDF

Source

Publication Analysis

Top Keywords

inspiratory expiratory
12
hysteresis area
12
inspiration expiration
8
flow-controlled expiration
8
expiratory compliance
8
expiratory flow
8
flow rate
8
positive end-expiratory
8
end-expiratory pressure
8
pressure peep
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!