AI Article Synopsis

Article Abstract

Splinting is the standard care for stabilizing replanted or repositioned permanent teeth following trauma. Traditionally, semirigid splints are used to stabilize a repositioned tooth, with support provided by adjacent teeth. However, in cases when the adjacent teeth are wide and/or can only provide minimal anchorage and support, it is difficult to fix the luxated tooth to its original position. This case report describes how a clear vacuum-formed splint was used to reposition and stabilize an avulsed maxillary left central incisor. Due to the avulsion, an unerupted canine, and partially erupted premolars, it was difficult to fabricate a traditional splint, hence the creation of the vacuum-formed splint.

Download full-text PDF

Source

Publication Analysis

Top Keywords

vacuum-formed splint
12
central incisor
8
case report
8
adjacent teeth
8
repositioning laterally
4
laterally luxated
4
luxated maxillary
4
maxillary central
4
incisor vacuum-formed
4
splint
4

Similar Publications

Introduction: This study performed a 3-dimensional analysis of tooth movement during orthodontic retention to assess the effectiveness of double retention (fixed and removable) in preventing undesired tooth movement.

Methods: One hundred randomly selected patients were included at the initiation of double orthodontic retention with fixed retainers and vacuum-formed splints (recommended to be worn 22 h/d) in both arches. Intraoral scans were performed directly (T0), 1 month (n = 88), 3 months (T2) (n = 78), and 6 months (T3) (n = 66) after retainer bonding.

View Article and Find Full Text PDF

Investigation of the cleaning performance of commercial orthodontic cleaning tablets regarding biofilm removal on PMMA test specimens : An ex vivo study.

J Orofac Orthop

June 2023

CharitéCenter 3 for Oral Health Sciences (CC 3), Department of Orthodontics and Dentofacial Orthopedics, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197, Berlin, Germany.

Purpose: The purpose of this ex vivo study was to compare the cleaning performance of three commercially available orthodontic cleaners on polymethyl methacrylate (PMMA) test specimens covered with biofilm.

Methods: Twenty subjects wore an individually manufactured vacuum-formed maxillary splint with four integrated PMMA test specimens for 7 days. The four test specimens were located on the buccal surfaces of the maxillary molars.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to review various materials and methods used for wear testing of occlusal devices and their antagonists, both in laboratory settings (in vitro) and clinical settings (in vivo).
  • A thorough electronic search identified 115 studies, from which 11 were selected for review, revealing that PEEK materials showed the least wear, while vacuum-formed devices experienced the most.
  • The authors concluded that there's a need for standardized wear testing protocols due to inconsistencies in current methodologies, and emphasized the necessity of more clinical studies, particularly for 3D printed materials.
View Article and Find Full Text PDF

Diagnostic and treatment protocol for a patient with temporomandibular disorder using a stabilization splint and temporary anchorage devices.

Am J Orthod Dentofacial Orthop

May 2021

State Key Laboratory of Oral Diseases, and National Clinical Research Center for Oral Diseases, and Department of Orthodontics and Pediatric Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China. Electronic address:

Treatment of orthodontic patients with temporomandibular disorder (TMD) is challenging for orthodontists because of the TMD signs and symptoms and unstable mandible position, which may lead to improper diagnosis and treatment design. This case report presents a 22-year-old woman with proclined maxillary incisors and TMD. First, stabilization splint therapy was implemented to eliminate temporomandibular joint pain and to obtain the stable adapted centric posture.

View Article and Find Full Text PDF

Comparison of hardness and polishability of various occlusal splint materials.

J Mech Behav Biomed Mater

March 2021

Faculty of Dentistry, Sir John Walsh Research Institute, University of Otago, New Zealand. Electronic address:

Objectives: To measure polishability of occlusal splint materials manufactured by various methods.

Methods: Seven occlusal splint materials manufactured by four different methods - Heat cured (Vertex Rapid simplified Clear), CAD-milled (Ceramill a-splint), Vacuum-formed (Proform splint) and 3D-printed (Freeprint Ortho, KeySplint Soft, DentaClear and FreePrint Splint 2.0) were tested for gloss, roughness, and surface hardness and elastic modulus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!