Background: A lack of evidence is present in literature regarding the clinical relevance of micropollution and bacterial contamination present on customized titanium abutments following laboratory stages and steaming cleaning procedures. To preserve abutments from such pollutants, plasma of argon cleaning of customized abutments was advocated.
Aim: The aim of this prospective, randomized, match-paired, triple-blinded, controlled, clinical trial is to longitudinally assess radiographical marginal bone-level changes around implants restored according to the platform switching and "one-abutment-one-time" concepts, using commercially available abutments, with and without plasma of argon cleaning treatment after customization.
Materials And Methods: Thirty patients with thin gingival biotype, a history of periodontal disease, and in general good health received one implant in the anterior maxilla or premolar region. Patients were randomly assigned to control (abutment subjected only to usually adopted cleaning protocol by steam) and test group (abutment subjected to plasma of argon treatment). Periapical standardized digital radiographs were taken at the time of crown connection (T0), 6 (T1) and 24 months after the final restoration (T2). Average mesial-distal bone-level changes mean values with standard deviations (SD) were calculated. The Mann-Whitney U-test was selected to identify differences in bone-level changes between test and control groups.
Results: An average interproximal bone loss of 0.16 mm (SD: 0.17) and 0.07 mm (SD: 0.34) was revealed in the control and test group at 6 months (T1), respectively, while after 24 months, groups showed a mean bone-level changes of 0.38 mm (SD: 0.44) and 0.11 mm (SD: 0.14), respectively. Statistically significant differences among control and test groups were found at both time points. Intergroup comparison relived absence of statistically significant difference.
Conclusion: Plasma-cleaning treatment of implant titanium abutments, together with platform switching and one-abutment-one-time concepts, could be favorable in terms of hard-tissue-level changes, also in critical conditions such as in patients with a history of periodontal disease, presenting thin gingival biotype.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/clr.12290 | DOI Listing |
Cureus
December 2024
Department of Diagnostic Pathology, Miyazaki Prefectural Miyazaki Hospital, Miyazaki, JPN.
Pleomorphic adenoma of the trachea is a rare benign tumor, often challenging to diagnose due to nonspecific symptoms. We report a case of a 72-year-old female with a 10-year history of presumed bronchial asthma, presenting with persistent dyspnea. Preoperative assessment for breast cancer surgery revealed severe obstructive ventilatory impairment.
View Article and Find Full Text PDFPathogens
December 2024
Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.
Periprosthetic joint infections occur in 1-2% of all patients undergoing prosthetic joint surgeries. Although strong efforts have been made to reduce infection rates, conventional therapies like one- or two-stage revisions have failed to lower the infection rates. Cold atmospheric plasma (CAP) has shown promising results in reducing bacterial loads on surfaces.
View Article and Find Full Text PDFBiomedicines
January 2025
Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 300, Taiwan.
: Cold atmospheric plasma (CAP) has been demonstrated as an adjustable device to generate various combinations of short-lived reactive oxygen and nitrogen species (RONS) and as a promising appliance for cancer therapy. This study investigated the effects of direct and indirect treatments of Argon-based CAP to cancer cells (A2058, A549, U2OS and BCC) and fibroblasts (NIH3T3 and L929) on cell viability. We also aimed to understand whether plasma-generated RONS were involved in this process using genetic evidence.
View Article and Find Full Text PDFMedicine (Baltimore)
January 2025
Department of Gastroenterology, The Affiliated People's Hospital of Ningbo University, Ningbo, China.
Rationale: Gastric antral vascular ectasia (GAVE) is a rare acquired lesion characterized by vascular dilation in the gastric antrum, frequently results in occult or overt gastrointestinal bleeding. Endoscopic intervention remains the cornerstone of therapy. Argon plasma coagulation was previously considered a first treatment option.
View Article and Find Full Text PDFResearch (Wash D C)
January 2025
School of Integrated Circuits and Beijing Advanced Innovation Center for Integrated Circuits, Peking University, Beijing 100871, China.
Edge contact is essential for achieving the ultimate device pitch scaling of stacked nanosheet transistors with monolayer 2-dimensional (2D) channels. However, due to large edge-contact resistance between 2D channels and contact metal, there is currently a lack of high-performance edge-contact device technology for 2D material channels. Here, we report high-performance edge-contact monolayer molybdenum disulfide (MoS) field-effect transistors (FETs) utilizing well-controlled plasma etching techniques.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!